Non-contact high precision pulse-rate monitoring system for moving subjects in different motion states
Qing Zhang1, Xingsen Lin1, Yuxin Zhang1
1School of Biomedical Engineering, Hainan University, Haikou, 570228, Hainan, China.
Abstract:
Remote photoplethysmography (rPPG) enables contact-free monitoring of the pulse rate by using a color camera. The fundamental limitation is that motion artifacts and changes in ambient light conditions greatly affect the accuracy of pulse-rate monitoring. We propose use of a high-speed camera and a motion suppression algorithm with high computational efficiency. This system incorporates a number of major improvements including reproduction of pulse wave details, high-precision pulse-rate monitoring of moving subjects, and excellent scene scalability. A series of quantization methods were used to evaluate the effect of different frame rates and different algorithms in pulse-rate monitoring of moving subjects. The experimental results show that use of 180-fps video and a Plane-Orthogonal-to-Skin (POS) algorithm can produce high-precision pulse-rate monitoring results with mean absolute error can be less than 5 bpm and the relative accuracy reaching 94.5%. Thus, it has significant potential to improve personal health care and intelligent health monitoring.
More Related Videos
08:09Multifunctional Setup for Studying Human Motor Control Using Transcranial Magnetic Stimulation, Electromyography, Motion Capture, and Virtual Reality
Published on: September 3, 2015
04:06Author Spotlight: Enhancing Remote Rehabilitation with Virtual Reality and Electromyography
Published on: January 12, 2024
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Holter Monitor: 24-Hour Monitoring