Related Experiment Video
Updated: Jul 22, 2025

Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
Three-in-one covalent organic framework nanozyme: Self-reporting, self-correcting and light-responsive for
Ling Liang1, Yuting Jiang1, Fengping Liu1
1State Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources, School of Chemistry and Pharmaceutical Science of Guangxi Normal University, Guilin, 541004, PR China.
Abstract:
Most current redox-type nanozyme-based colorimetric sensing platforms are susceptible to interference from the reductant when using chromogenic probe, and the unstable H2O2 used in the peroxidase-like nanozyme-based systems is prone to difficulty in sensing signal reproducibility, while peroxidase-like nanozyme with oxidase-mimicking activity is easy to bring background interference by O2. Since the strong structural designability of covalent organic frameworks (COFs) endows them great application value in the sensing fields, therefore, we envision the construction a COF oxidase-like nanozyme-based controllable sensing system that integrates self-reporting, self-correcting and light-responsive functions to avoid these affects. Herein, 3-nitrotyrosine (3-NT) biomarker was selected as model analyte. 1,3,5-triformylphloroglucinol (Tp) and 3,6-diaminoacridine (DA) were acted as building monomers of the multifunctional COF nanozyme (termed as TpDA). Owing to the excellent light-responsive oxidase-mimicking property of TpDA, 3-NT can be efficiently oxidized, the inner filter effect (IFE) between TpDA and the 3-NT oxidation product greatly quenches the intrinsic fluorescence of TpDA, making it a controllable self-reporting system for fluorescence turn-off sensing 3-NT. Additionally, the excessive reactive oxygen species (ROS) that generated continuously during photocatalysis can resist the interference of endogenous reductants. This study not only provides new insights to avoid the interference of H2O2, background and reductants from conventional redox-type nanozyme-based colorimetric systems but also opens avenues to rational construct versatile COF nanozyme-based sensor.
More Related Videos
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
10:38Synthesis and Calibration of Phosphorescent Nanoprobes for Oxygen Imaging in Biological Systems
Published on: March 3, 2010