Comparing microscope light-associated glare and comfort between heads-up 3D digital and conventional microscopes in
Vincent Gualino1, Kevin Pierne2, Anthony Manassero3
1Department of Ophthalmology, Clinique Honoré Cave, Montauban, France v.gual@hotmail.fr.
Objective:
To compare subjective levels of comfort and visual experiences related to microscope light in patients undergoing their first cataract surgery with topical anaesthesia using a digital microscope (the NGENUITY three-dimensional (3D) visualisation system) or a conventional microscope.
Methods And Analysis:
A prospective, randomised, single-blinded, parallel-group, multicentre, interventional study. Patients (n=128) were randomly assigned to one of two treatment groups: the experimental group (n=63) had surgery using the digital microscope and the control group (n=65) had surgery with a conventional microscope. The primary outcome was patients' subjective experience of glare from the microscope light during surgery on a numerical scale from 0 to 10. Key secondary outcomes were patients' subjective levels of comfort and visual experiences related to the microscope light.
Results:
The experimental group reported significantly lower levels of glare; median levels were 1.0 (0.0-4.0) for the experimental group vs 3.0 (0.0-6.0) for the control group (p=0.027). They also reported higher levels of comfort; median ratings were 8.0 (6.5-10.0) in the experimental group and 7.0 (5.0-9.0) in controls (p=0.026). There were no group differences in ratings of subjective pain or visual disturbances. Median microscope light intensity was lower in the experimental group than controls; 3425.0 (2296.0-4300.0) Lux vs 24 279.0 (16 000.0-26 500.0) Lux (p<0.0001), respectively.
Conclusion:
Compared with conventional microscopes, the NGENUITY 3D visualisation system allows surgeons to operate with lower levels of light exposure, resulting in significantly less glare and improved comfort in patients undergoing cataract surgery.
Trial Registration Number:
NCT05085314.
More Related Videos
06:19Comparison of Three Clinical Stereoscopic Methods for Measuring Binocular Visual Function During Amblyopic Treatment in Unilateral Amblyopia
Published on: September 27, 2024
07:45Assessing Binocular Central Visual Field and Binocular Eye Movements in a Dichoptic Viewing Condition
Published on: July 21, 2020
Related Concept Videos
Three-Dimensional Microscopy in Microbiology
Confocal Fluorescence Microscopy
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...