Methods for real-time feature-guided image fusion of intrasurgical volumetric optical coherence tomography with
Robert M Trout1, Christian Viehland1, Jianwei D Li1
1Department of Biomedical Engineering, Duke University, 101 Science Drive, Durham, NC 27708, USA.
Abstract:
4D-microscope-integrated optical coherence tomography (4D-MIOCT) is an emergent multimodal imaging technology in which live volumetric OCT (4D-OCT) is implemented in tandem with standard stereo color microscopy. 4D-OCT provides ophthalmic surgeons with many useful visual cues not available in standard microscopy; however it is challenging for the surgeon to effectively integrate cues from simultaneous-but-separate imaging in real-time. In this work, we demonstrate progress towards solving this challenge via the fusion of data from each modality guided by segmented 3D features. In this way, a more readily interpretable visualization that combines and registers important cues from both modalities is presented to the surgeon.
More Related Videos
12:22Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
Published on: August 4, 2018
12:54Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...