Predicting partitioning from low density polyethylene to blood and adipose tissue by linear solvation energy
Nadin Ulrich1, Alexander Böhme1, Adrian Benedict Strobel2
1Department of Ecological Chemistry, Helmholtz Centre for Environmental Research-UFZ, Leipzig, Germany.
Abstract:
The variety of polymers utilized in medical devices demands for testing of extractables and leachables according to ISO 10993-18:2020 in combination with ISO 10993-1:2018. The extraction of the materials involves the use of organic solvents as well as aqueous buffers to cover a wide range of polarity and pH-values, respectively. To estimate patient exposure to chemicals leaching from a polymer in direct body contact, simulating solvents are applied to best mimic the solubilization and partitioning behavior of the related tissue or body fluid. Here we apply linear solvation energy relationship (LSER) models to predict blood/water and adipose tissue/water partition coefficients. We suggest this predictive approach to project levels of potential leachables, design extraction experiments, and to identify the optimal composition of simulating extraction solvents. We compare our predictions to LSER predictions for commonly applied surrogates like ethanol/water mixtures, butanol, and octanol as well as olive oil, butanone, 1,4-dioxane for blood and adipose tissue, respectively. We therefore selected a set of 26 experimentally determined blood/water partition coefficients and 33 adipose tissue/water partition coefficients, where we demonstrate that based on the root mean squared error rmse the LSER approach performs better than surrogates like octanol or butanol and equally well as 60:40 ethanol/water for blood. For adipose tissue/water partitioning, the experimentally determined octanol/water partition coefficient performs best but the rmse is at the same range as our LSER approach based on experimentally determined descriptors. Further, we applied our approach for 248 extractables where we calculated blood/low density polyethylene (LDPE) and adipose tissue/LDPE partition coefficients. By this approach, we successfully identified chemicals of potential interest to a toxicological evaluation based on the total risk score.
More Related Videos
07:31Author Spotlight: Advancing Cell Membrane Biophysics - Exploring Interactions and Challenges Through Experimental and Computational Approaches
Published on: September 1, 2023
08:52Adipo-Clear: A Tissue Clearing Method for Three-Dimensional Imaging of Adipose Tissue
Published on: July 28, 2018
Related Concept Videos
Physiological Pharmacokinetic Models: Assumption with Protein Binding
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Extraction: Partition and Distribution Coefficients
For extracting a solute from an aqueous phase into an...
Mechanistic Models: Compartment Models in Individual and Population Analysis
Two-Compartment Open Model: Extravascular Administration
The absorption exponent (ka) indicates the speed at which the drug...
Three-Compartment Open Model