Related Experiment Video
Updated: Jul 21, 2025

Characterization of Metabolic Status in Nonhuman Primates with the Intravenous Glucose Tolerance Test
Published on: November 13, 2016
Glucose variability in 6-12-month-old healthy infants
Michael Hauschild1, Cathriona Monnard2, Alison L Eldridge2
1Pediatric Endocrinology, Diabetes and Obesity Unit, Department Woman-Mother-Child, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
Background:
Metabolic programming of glucose homeostasis in the first 1,000 days of life may impact lifelong metabolic and cardiovascular health. Continuous glucose monitoring (CGM) devices may help measure the impact of dietary intake on glucose rhythms and metabolism in infants during the complementary feeding period.
Objectives:
Demonstrate the feasibility of CGM to measure and quantify glucose variability in response to infant feeding and to evaluate associations between macronutrient meal composition and glucose variability.
Methods:
The "FreeStyle Libre Pro®" device interstitial glucose meter was applied to the anterior thigh of 10 healthy 6-12-month-old infants. Parents recorded food intake, time of feeding, and used daily dairies to record sleep time and duration. Descriptive statistics were employed for food intake, sleep and key glycemic parameters over three full days. Mixed linear models were used to assess glycemic changes.
Results:
Mid-day, afternoon, and evening feeds contained >30 g carbohydrate and induced higher 2-h iAUC (3.42, 3.41, and 3.50 mmol/L*h respectively) compared to early and mid-morning feedings with ≤25 g carbohydrates (iAUC 2.72 and 2.81 mmol/L*h, p < 0.05). Early morning and evening milk feedings contained approximately 9 g of fat and induced a longer time to reach maximal glucose value (Tmax; 75 and 68 min, respectively) compared to lower fat feedings (2.9-5.9 g; Tmax range: 34-60 min; p < 0.05). Incremental glucose value at time of food intake (C0) increased significantly from 0.24 ± 0.39 mM in early morning to 1.07 ± 0.57 mM in the evening (p < 0.05). Over the day, 70% of glucose values remained within the normal range (3.5-5.5 mmol/L), 10% were between 5.5-10 mmol/L, and 20% were < 3.5 mmol/L.
Conclusion:
Our data support the feasibility of using CGM to measure glucose in 6-12-month-old infants. The observation of possible diurnal glucose variability and typical glucose values may have implications for future studies investigating metabolic adaptation to nutritional intake in early life.
Related Concept Videos
Glucose Homeostasis: Regulation of Blood Glucose
During fasting, when blood glucose levels are low, the pancreas secretes glucagon. it...
Glucose Absorption Into the Small Intestine
Glucose Transporters
Facilitated diffusion-glucose transporters (GLUTs) are encoded by the solute-linked carrier (SLC) family 2, subfamily A gene family, or SLC2A. The 14 GLUT protein members are distributed into three classes:
Hormones Regulating Blood Glucose
In addition to accelerating glucose uptake and utilization, insulin has...
Glucose Homeostasis: Pancreatic Islets and Insulin Secretion
Insulin and C-peptide are...
Hypoglycemia and Glucagon