Related Experiment Video
Updated: Jul 21, 2025

Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Correlations between Ratings and Technical Measurements in Hand-Intensive Work
Gunilla Dahlgren1, Per Liv1, Fredrik Öhberg2
1Section of Sustainable Health, Department of Public Health and Clinical Medicine, Umeå University, S-901 87 Umeå, Sweden.
Abstract:
An accurate rating of hand activity and force is essential in risk assessment and for the effective prevention of work-related musculoskeletal disorders. However, it is unclear whether the subjective ratings of workers and observers correlate to corresponding objective technical measures of exposure. Fifty-nine workers were video recorded while performing a hand-intensive work task at their workplace. Self-ratings of hand activity level (HAL) and force (Borg CR10) using the Hand Activity Threshold Limit Value® were assessed. Four ergonomist observers, in two pairs, also rated the hand activity and force level for each worker from video recordings. Wrist angular velocity was measured using inertial movement units. Muscle activity in the forearm muscles flexor carpi radialis (FCR) and extensor carpi radialis (ECR) was measured with electromyography root mean square values (RMS) and normalized to maximal voluntary electrical activation (MVE). Kendall's tau-b correlations were statistically significant between self-rated hand activity and wrist angular velocity at the 10th, 50th, and 90th percentiles (0.26, 0.31, and 0.23) and for the ratings of observers (0.32, 0.41, and 0.34). Significant correlations for force measures were found only for observer-ratings in five of eight measures (FCR 50th percentile 0.29, time > 10%MVE 0.43, time > 30%MVE 0.44, time < 5% -0.47) and ECR (time > 30%MVE 0.26). The higher magnitude of correlation for observer-ratings suggests that they may be preferred to the self-ratings of workers. When possible, objective technical measures of wrist angular velocity and muscle activity should be preferred to subjective ratings when assessing risks of work-related musculoskeletal disorders.
Related Concept Videos
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Calibration Curves: Correlation Coefficient
Coefficient of Correlation
If you suspect a linear relationship between x and y, then r can measure how strong the linear relationship is.
What the VALUE of r tells us:
The value of r is always between –1 and +1: –1 ≤ r ≤ 1.
The size of the correlation r indicates the...
Quantifying Work
Calculating and Interpreting the Linear Correlation Coefficient
Correlation of Experimental Data
For example, a spherical particle moving through a viscous fluid experiences drag. Dimensional analysis shows that the drag force depends on the particle's diameter, velocity,...

