Related Experiment Video
Updated: Jul 21, 2025

A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
Experimental Calibration of a Homogeneous Substitute Material Model for Reinforced High-Performance Concrete Modeling
Jarosław Siwiński1, Anna Szcześniak1, Katarzyna Kubiak2
1Faculty of Civil Engineering and Geodesy, Military University of Technology, 2 Gen. Sylwestra Kaliskiego Street, 00-908 Warsaw, Poland.
Abstract:
The purpose of this work was to develop a substitute material model for the analysis of reinforced concrete structures. This paper presents proposals to solve the problem of limited calculation time, both to perform simulation models and to perform effective numerical or analytical analyses of structural elements in order to achieve results consistent with experimental results. Achieving this aim is conditional upon the determination of the material model parameters, taking into account the type of structure, the system of reinforcement, and the static strength-deformation parameters of the component materials. A universal procedure is proposed for determining the parameters of the substitute material model on the basis of the homogenization function, in which the homogenization coefficient is assumed as being equal to the effective reinforcement ratio of real reinforced concrete structural elements. In addition, the introduction of a new concrete constraint coefficient to this procedure, which corresponds to the proportionality coefficient of biaxial to uniaxial compressive strength, is proposed. On the basis of the conducted comparative analyses, the possibility of using the hypothetical substitute material model for the design of building elements and structures was confirmed. The average values of the obtained results for individual research series did not differ from the experimental results by more than 8.5%, for both the numerical and analytical models.
More Related Videos
11:07Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
10:00Experimental Protocol to Determine the Chloride Threshold Value for Corrosion in Samples Taken from Reinforced Concrete Structures
Published on: August 31, 2017
Related Concept Videos
Non-destructive Tests for Concrete Strength
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Measurement of Air Content in Concrete
The pressure method,...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Fiber Reinforced Concrete
Impact Strength of Concrete