James A Crowhurst1, Jason Tse2, Negar Mirjalili2
1Cardiology Department, The Prince Charles Hospital, Chermside, Queensland, Australia; School of Medicine, University of Queensland, St Lucia, Queensland, Australia; School of Clinical Sciences, Queensland University of Technology, Brisbane, Queensland, Australia.
Abstract:
Continuous exposure to low-level scattered radiation to staff performing cardiac angiography and intervention is of concern. A novel shielding solution (NSS) (Rampart IC M1128) has the potential to provide greater shielding for staff present at the table-side. This study aimed to investigate the effectiveness of the NSS compared with a traditional shielding solution (TSS) in a randomized controlled trial that enrolled 100 patients who underwent cardiac angiography and/or intervention which were randomized to the NSS or TSS. Baseline patient characteristics and radiation dose data were collected. Staff who were scrubbed at the table-side wore 5 real-time dosimeters on the head, collar, waist, ankle, and under the apron. The median primary operator radiation dose was significantly lower (p <0.001) for all dosimeter locations with the NSS when compared with the TSS, being reduced by 86%, 80.0%, 100%, and 50.0% for the head, collar, waist, and leg respectively. Median under-apron dose was 0.0 µSv for both NSS and TSS. Median second operator dose was reduced by 100%, 100%, and 100% for the head, collar, and waist respectively (p <0.001). Median NSS and TSS dose at the ankle and under apron was 0.0 µSv. Median scrub nurse dose was reduced by 50% and 100% for the head and collar respectively (p <0.001). Median NSS and TSS dose at the waist, ankle, and under apron was 0.0 µSv. In conclusion, the NSS tested in this study demonstrates a significant decrease in radiation dose to operators and scrub nurses when compared with traditional radiation protection measures.
More Related Videos
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...