Related Experiment Video
Updated: Jul 19, 2025

Subject-specific Musculoskeletal Model for Studying Bone Strain During Dynamic Motion
Published on: April 11, 2018
Does High Medial Elbow Stress During Pitching Compromise the Dynamic Stabilizers of The Elbow?
Malachy P McHugh1, Michael J Mullaney1
1Nicholas Institute of Sports Medicine and Athletic Trauma.
Background:
The flexor carpi ulnaris (FCU) and flexor digitorum superficialis (FDS) are thought to provide dynamic stability to the medial elbow, with a lesser contribution from the pronator teres (PT).
Hypothesis/Purpose:
The purpose of this study was to determine if baseball pitchers with higher valgus elbow torque experience greater FCU and FDS strength loss.
Study Design:
Controlled Laboratory Study.
Methods:
A pilot study was performed to determine if middle and ring finger flexion strength tests preferentially activated the FCU and FDS versus the PT (10 men age 36±12 yr). EMG amplitudes, expressed as percent of maximal voluntary contraction (MVC) were compared between tests and muscles. In a field study of college baseball pitchers, middle finger, ring finger and grip strength were tested prior to, immediately after, and one day after 14 pitching performances in 10 pitchers (21±2 yr). Elbow valgus torque was measured from an inertial measurement unit, housed in a compression sleeve and pitchers were categorized as having high or low valgus torque.
Results:
For the pilot study EMG activations were 74% FDS, 66% FCU and 35% PT for the middle finger test (muscle effect p=0.032) and 93% FCU, 61% FDS and 23% PT for the ring finger test (muscle effect p=0.005). In the field study, pitchers with high valgus torque showed marked post-game middle finger fatigue (88% of baseline) and incomplete recovery the following day (95%), while pitchers with low valgus torque showed no strength loss (107% post game, 106% a day later; group x time p=0.022). Results were similar for ring finger strength (high torque: 94% post game 96% a day later; low torque: 114% post game 107% a day later; group x time p=0.048). By contrast, grip strength was not different between pitchers with high versus low valgus torque (p=0.143).
Conclusion:
High medial elbow stress during pitching fatigues the dynamic stabilizers of the medial elbow.
Level Of Evidence:
Level 3©The Author(s).
Related Concept Videos
Bones of the Upper Limb: Ulna
Transformation of Plane Stress
Residual Stresses in Circular Shafts
Circular Shafts - Elastoplastic Materials
As torque on the...
Stability of Equilibrium Configuration: Problem Solving
Problem-solving in the context of the stability of equilibrium configuration...
Muscles that Move the Forearm
Forearm Flexors
The biceps brachii, brachialis, and brachioradialis are forearm flexors. The biceps brachii is made up of two heads. Its long head originates at the supraglenoid tubercle of the scapula, whereas that of the short head is...

