Related Experiment Video
Updated: Jul 26, 2026

Establishing In Situ Closed Circuit Perfusion of Lower Abdominal Organs and Hind Limbs in Mice
Published on: August 13, 2020
Tissue perfusion pressure enables continuous hemodynamic evaluation and risk prediction in the intensive care unit
Anand Chandrasekhar1,2, Raimon Padrós-Valls2,3, Roger Pallarès-López2,3
1Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA.
None:
Treatment of circulatory shock in critically ill patients requires management of blood pressure using invasive monitoring, but uncertainty remains as to optimal individual blood pressure targets. Critical closing pressure, which refers to the arterial pressure when blood flow stops, can provide a fundamental measure of vascular tone in response to disease and therapy, but it has not previously been possible to measure this parameter routinely in clinical care. Here we describe a method to continuously measure critical closing pressure in the systemic circulation using readily available blood pressure monitors and then show that tissue perfusion pressure (TPP), defined as the difference between mean arterial pressure and critical closing pressure, provides unique information compared to other hemodynamic parameters. Using analyses of 5,988 admissions to a modern cardiac intensive care unit, and externally validated with 864 admissions to another institution, we show that TPP can predict the risk of mortality, length of hospital stay and peak blood lactate levels. These results indicate that TPP may provide an additional target for blood pressure optimization in patients with circulatory shock.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessing Blood pressure in the Leg
Preparation:
Pre-Procedural Guidelines for Assessing Blood Pressure

