Related Experiment Video
Updated: Jun 17, 2026

Using a Split-belt Treadmill to Evaluate Generalization of Human Locomotor Adaptation
Published on: August 23, 2017
Reliability of a 60-min treadmill running protocol in the heat: The journal Temperature toolbox
Toby Mündel1, Simon Gilmour2, Marlena Kruger3
1School of Sport Exercise and Nutrition, Massey University, Palmerston North, New Zealand.
Abstract:
We determined the reliability of a 60-min treadmill protocol in the heat when spaced >4 weeks apart, longer than the test-retest duration of 1 week found in the literature. Nine unacclimated, trained males (age: 31 ± 8 y; VO2peak: 60 ± 6 ml∙kg-1∙min-1) undertook a 15 min self-paced time-trial pre-loaded with 45 min of running at 70% of individual ventilatory threshold (11.2 ± 0.3 km∙h-1) in 30 ± 1°C (53 ± 5% relative humidity). They repeated this following 40 ± 14 and 76 ± 26 days, with pre-trial standardization of diet and exercise for 48 h. When considering trial 1 as a familiarization, change in core temperature (∆Tcore) during the first 45 min (∆2.0 ± 0.2°C) between trials 2 and 3 yielded bias and 95% limits of agreement (LoA) of -0.10 ± 0.43°C, standard error of measurement (SEM) of 0.13°C and intraclass correlation coefficient (ICC) of 0.75, more reliable than measures of baseline Tcore (36.9 ± 0.2°C; LoA: -0.23 ± 0.90°C; SEM: 0.22°C; ICC: 0.03) and Tcore at 45 min during exercise (38.9 ± 0.4°C; LoA: 0.32 ± 1.12°C; SEM: 0.28°C; ICC: 0.15). The coefficient of variation (CV) between trials 2 and 3 for distance run during the 15 min time-trial was 2.1 ± 2.0% with LoA of 0.001 ± 0.253 km and SEM of 0.037 km. This protocol is reliable spaced ~5 weeks apart when considering the most commonly accepted limit of <5% CV for performance, reinforced by reliability of the ΔTcore being 0.1 ± 0.4°C.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes