Filtering-induced changes of pulse transmit time across different ages: a neglected concern in

Shangdi Liao1, Haipeng Liu2, Wan-Hua Lin3

  • 1Department of Electronic and Electrical Engineering, Southern University of Science and Technology, Shenzhen, China.

Frontiers in Physiology
|August 10, 2023
PubMed

Insights

Filtering photoplethysmography (PPG) signals significantly alters pulse transit time (PTT) measurements, with effects varying by age and PPG feature definition. These findings are crucial for accurate wearable blood pressure monitoring.

Area of Science:

  • Biomedical Engineering
  • Physiological Measurement
  • Wearable Technology

Background:

  • Pulse transit time (PTT) is vital for cuffless blood pressure monitoring using photoplethysmography (PPG).
  • Signal filtering in wearable PPG sensors can introduce inaccuracies in PTT estimation.
  • Limited research exists on how filtering affects PTT across different age groups.

Purpose of the Study:

  • To quantitatively assess the impact of age and PTT definition on filtering-induced PTT changes.
  • To investigate the influence of infinite impulse response (IIR) filtering on PTT measurements.
  • To provide insights for improving PPG-based cuffless blood pressure accuracy.

Main Methods:

  • Recruited 100 healthy subjects across five age groups (20-60+ years).
  • Recorded simultaneous electrocardiogram (ECG) and PPG signals.
  • Calculated PTT using eight definitions based on PPG waveform features and compared filtered vs. unfiltered signals, analyzing age-group differences via ANOVA.

Main Results:

  • Filtering significantly altered PTT, influenced by both age and the specific PTT definition (p < 0.001).
  • Aging showed a consistent trend in filtering-induced PTT changes across all definitions.
  • PTT defined by the PPG maximum peak exhibited minimal filtering changes (16.16 ms, 5.65%), while the maximum first derivative showed the strongest age correlation (R-squared: 0.47).

Conclusions:

  • Age and PTT definition critically impact filtering-induced PTT changes.
  • These factors must be considered for enhancing the accuracy of wearable PPG-based blood pressure devices.
  • Further research is needed to optimize filtering and PTT definitions for diverse populations.

Related Concept Videos

Sites for measruring blood pressure01:21

Sites for measruring blood pressure

Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.9K
Special considerations while measuring blood pressure01:28

Special considerations while measuring blood pressure

When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
756
Measurement of Blood Pressure01:17

Measurement of Blood Pressure

Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
1.0K
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
758
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
1.1K
Pulse01:16

Pulse

When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...