Resolving Water, Proteins, and Lipids from In Vivo Confocal Raman Spectra of Stratum Corneum through a Chemometric Approach
Published on: September 26, 2019
Correction for Extrinsic Background in Raman Hyperspectral Images.
J Nicholas Taylor1,2, Aurélien Pélissier1,3, Kentaro Mochizuki4
1Research Institute for Electronic Science, Hokkaido University, Kita 20, Nishi 10, Kita-ku, Sapporo 001-0020, Japan.
Extrinsic background in Raman hyperspectral microscopy can skew results. A new extrinsic background correction (EBC) method accurately removes this noise, improving biological sample classification and enabling broader applications.
Area of Science:
- Biological imaging
- Biomedical imaging
- Chemical analysis
Background:
- Raman hyperspectral microscopy is vital for biological and biomedical imaging.
- Spectral fluctuations and contamination challenge Raman spectroscopy analysis.
- Existing methods struggle with extrinsic background, impacting biological applications.
Purpose of the Study:
- To address the issue of extrinsic background in Raman hyperspectral images.
- To develop a method for mitigating extrinsic background effects on classification models.
- To improve the accuracy of distinguishing between benign and malignant samples.
Main Methods:
- Development of extrinsic background correction (EBC).
- Application of EBC to Raman hyperspectral images.
- Classification of follicular thyroid cell lines with and without EBC.
Main Results:
- Extrinsic background significantly impacts classification model accuracy.
- EBC effectively reduces extrinsic background while preserving spectral biological characteristics.
- Classification accuracy improved after applying EBC.
Conclusions:
- EBC is a crucial method for accurate analysis of Raman hyperspectral images.
- The developed EBC method enhances the reliability of biological and biomedical imaging.
- The EBC methodology is adaptable for other hyperspectral and grayscale image types.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
NMR Spectrometers: Resolution and Error Correction
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...