Comparison of Accuracy of Six Modern Intraocular Lens Power Calculation Formulas
Ji Hyun Yoon1, Woong-Joo Whang1
1Department of Ophthalmology, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Korean Journal of Ophthalmology : KJO
|August 10, 2023
Summary
Six modern intraocular lens (IOL) power calculation formulas showed comparable accuracy in predicting refractive outcomes after cataract surgery. The Barrett Universal II (BUII) formula demonstrated the highest accuracy overall.
Area of Science:
- Ophthalmology
- Biomedical Engineering
- Optics
Background:
- Cataract surgery is a common procedure for vision restoration.
- Accurate intraocular lens (IOL) power calculation is crucial for achieving desired refractive outcomes.
- Modern IOL power calculation formulas aim to improve refractive predictability.
Purpose of the Study:
- To compare the accuracy of six contemporary IOL power calculation formulas.
- To evaluate the prediction error of these formulas in standard cataract surgery.
- To analyze formula performance across different axial lengths (AL).
Main Methods:
- Retrospective review of 203 eyes undergoing phacoemulsification and IOL implantation.
- Biometric data obtained using partial coherence interferometry.
- Evaluation of Barrett Universal II (BUII), EVO 2.0, Hill-RBF 3.0, Hoffer QST, Kane, and PEARL-DGS formulas.
- Analysis of prediction error, correlation with AL and corneal power, and subgroup analysis by AL.
Main Results:
- No significant difference in absolute prediction errors among the six formulas overall.
- BUII and Hill-RBF 3.0 showed a higher percentage of eyes within ±0.50 D error compared to Hoffer QST (not significant after correction).
- BUII formula exhibited the highest accuracy, followed by PEARL-DGS, EVO 2.0, Kane, Hill-RBF 3.0, and Hoffer QST.
- Hoffer QST prediction error correlated significantly with AL; no formulas correlated with corneal power.
Conclusions:
- The six modern IOL power calculation formulas demonstrate comparable accuracy.
- Formula accuracy is consistent across various axial lengths.
- The BUII formula showed the highest performance index, indicating superior accuracy in this cohort.
Keywords:
Intraocular lens formula accuracyIntraocular lensesPower calculation formulasRefractive prediction error