Related Experiment Video
Updated: Jul 19, 2025

Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Free-Hand MIS TLIF without 3D Navigation-How to Achieve Low Radiation Exposure for Both Surgeon and Patient
Roberto Doria-Medina1, Ulrich Hubbe1, Christoph Scholz1
1Department of Neurosurgery, Medical Center, University of Freiburg, 79106 Freiburg, Germany.
Background:
Transforaminal lumbar interbody fusion (TLIF) is one of the most frequently performed spinal fusion techniques, and this minimally invasive (MIS) approach has advantages over the traditional open approach. A drawback is the higher radiation exposure for the surgeon when conventional fluoroscopy (2D-fluoroscopy) is used. While computer-assisted navigation (CAN) reduce the surgeon's radiation exposure, the patient's exposure is higher. When we investigated 2D-fluoroscopically guided and 3D-navigated MIS TLIF in a randomized controlled trial, we detected low radiation doses for both the surgeon and the patient in the 2D-fluoroscopy group. Therefore, we extended the dataset, and herein, we report the radiation-sparing surgical technique of 2D-fluoroscopy-guided MIS TLIF.
Methods:
Monosegmental and bisegmental MIS TLIF was performed on 24 patients in adherence to advanced radiation protection principles and a radiation-sparing surgical protocol. Dedicated dosemeters recorded patient and surgeon radiation exposure. For safety assessment, pedicle screw accuracy was graded according to the Gertzbein-Robbins classification.
Results:
In total, 99 of 102 (97.1%) pedicle screws were correctly positioned (Gertzbein grade A/B). No breach caused neurological symptoms or necessitated revision surgery. The effective radiation dose to the surgeon was 41 ± 12 µSv per segment. Fluoroscopy time was 64 ± 34 s and 75 ± 43 radiographic images per segment were performed. Patient radiation doses at the neck, chest, and umbilical area were 65 ± 40, 123 ± 116, and 823 ± 862 µSv per segment, respectively.
Conclusions:
Using a dedicated radiation-sparing free-hand technique, 2D-fluoroscopy-guided MIS TLIF is successfully achievable with low radiation exposure to both the surgeon and the patient. With this technique, the maximum annual radiation exposure to the surgeon will not be exceeded, even with workday use.
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...