Related Experiment Video
Updated: Jul 19, 2025

Atom Probe Tomography Studies on the CuIn,GaSe2 Grain Boundaries
Published on: April 22, 2013
Experimental Determination of the Charge Carrier Transport Models for Improving the Simulation of the HR GaAs:Cr
Petr Smolyanskiy1, Petr Burian1,2, Mateusz Sitarz3
1Institute of Experimental and Applied Physics, Czech Technical University in Prague, Husova 240/5, 110 00 Prague, Czech Republic.
Abstract:
The response of Timepix3 detectors with 300 µm and 500 µm thick HR GaAs:Cr sensors was studied with particle beams at the Danish Centre for Particle Therapy in Aarhus, Denmark. Therefore, the detectors were irradiated at different angles with protons of 240 MeV. The precise per-pixel time and energy measurements were exploited in order to determine the charge carrier transport properties. Using the tracks left by the penetrating charged particles hitting the sensor at the grazing angle, we were able to determine the charge collection efficiency, the charge carrier drift times across the sensor thickness, the dependency of the electron, and for the first time, the hole drift velocity on the electric field. Moreover, extracting the dependence of the charge cloud size on the interaction depth for different bias voltages, it was possible to determine the dependence of the diffusion coefficient on the applied bias voltage. A good agreement was found with the previously reported values for n-type GaAs. The measurements were conducted for different detector assemblies to estimate the systematic differences between them, and to generalize the results. The experimental findings were implemented into the Allpix Squared simulation framework and validated by a comparison of the measurement and simulation for the 241Am γ-ray source.
Related Concept Videos
Carrier Generation and Recombination
This process is given by the generation rate G and is efficient due to the conservation of momentum between the valence band maximum and conduction band minimum.
Indirect generation involves an...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Carrier Transport
Drift Current:
The drift of charge carriers is started by an external electric field (E). Charged particles, such as electrons and holes, experience an acceleration between collisions with lattice atoms. For electrons, this results in a drift velocity (vd) given by:

