Related Experiment Video For glucose-monitoring system
Updated: Jul 19, 2025

Studying the Hypothalamic Insulin Signal to Peripheral Glucose Intolerance with a Continuous Drug Infusion System into the Mouse Brain
Published on: January 4, 2018
Continuous Glucose Monitoring: A Possible Aid for Detecting Hypoglycemic Events during Insulin Tolerance Tests
1Department of Pediatrics, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.
Abstract:
The combined pituitary function test evaluates the anterior pituitary gland, while the insulin tolerance test evaluates growth hormone deficiencies. However, successful stimulation requires achieving an appropriate level of hypoglycemia. Close medical supervision for glucose monitoring is required during hypoglycemia induction and the test is often very tedious. In addition, a capillary blood sugar test (BST) and serum glucose levels may differ greatly. An alternative approach may be utilizing a continuous glucose-monitoring (CGM) system. We provide three cases in which CGM was successfully used alongside a standard BST and serum glucose levels during the combined pituitary function test to better detect and induce hypoglycemia. Three participants who were diagnosed with multiple pituitary hormone deficiencies during childhood were re-evaluated in adulthood; a Dexcom G6 CGM was used. The CGM sensor glucose and BST levels were simultaneously assessed for glycemic changes and when adequate hypoglycemia was reached during the combined pituitary function test. The CGM sensor glucose, BST, and serum glucose levels showed similar glucose trends in all three patients. A Bland-Altman analysis revealed that the CGM underestimated the BST values by approximately 9.68 mg/dL, and a Wilcoxon signed-rank test showed that the CGM and BST measurements significantly differed during the stimulation test (p = 0.003). Nevertheless, in all three cases, the CGM sensor mimicked the glycemic variability changes in the BST reading and assisted in monitoring appropriate hypoglycemia nadir. Thus, CGM can be used as a safe aid for clinicians to use during insulin tolerance tests where critical hypoglycemia is induced.
More Related Videos
08:13Study of In Vivo Glucose Metabolism in High-fat Diet-fed Mice Using Oral Glucose Tolerance Test OGTT and Insulin Tolerance Test ITT
Published on: January 7, 2018
07:35Author Spotlight: Investigating the Blood Glucose Homeostasis in Murine Brain Using a Cost-Effective Hyperglycemic And Hypoglycemic Clamp Technique
Published on: January 26, 2024
Related Concept Videos
Hypoglycemia and Glucagon
Oral Hypoglycemic Agents: Glinides
Glucose Homeostasis: Regulation of Blood Glucose
During fasting, when blood glucose levels are low, the pancreas secretes glucagon. it...
Hormones Regulating Blood Glucose
In addition to accelerating glucose uptake and utilization, insulin has...
Diabetes Mellitus: Type 2 and Gestational
Glucose Homeostasis: Pancreatic Islets and Insulin Secretion
Insulin and C-peptide are...