Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT01:25

Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT

39
Calcium-Scoring CT ScanA calcium-scoring CT scan, also known as coronary artery calcium (CAC) scan, detects calcium deposits in the coronary arteries. This test assesses the risk of coronary artery disease (CAD), which can lead to cardiovascular events such as angina, heart failure, and sudden cardiac arrest.A calcium-scoring CT scan is generally recommended for individuals at intermediate risk of CAD without symptoms. It includes:Men aged 40-75 and women aged 50-75: Especially those with a...
39
Computed Tomography01:10

Computed Tomography

4.6K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
4.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Structure-aware vessel enhancement network for low-dose contrast agent CT angiography imaging.

Physics in medicine and biology·2026
Same author

Inter-slice complementarity enhanced ring artifact removal using central region reinforced neural network.

Physics in medicine and biology·2025
Same author

PDS-MAR: a fine-grained projection-domain segmentation-based metal artifact reduction method for intraoperative CBCT images with guidewires.

Physics in medicine and biology·2023
Same author

Learnable PM diffusion coefficients and reformative coordinate attention network for low dose CT denoising.

Physics in medicine and biology·2023
Same author

Comparison and development of machine learning tools for the prediction of chronic obstructive pulmonary disease in the Chinese population.

Journal of translational medicine·2020
Same author

Transplanted senescent renal scattered tubular-like cells induce injury in the mouse kidney.

American journal of physiology. Renal physiology·2020

Related Experiment Video

Updated: Jul 19, 2025

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
13:44

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns

Published on: August 30, 2013

42.9K

A new projection correction based voting strategy for breast calcification artifact reduction.

Hui Tang1,2, Jiashun Wang1, Liang Sun1

  • 1Laboratory of Image Science and Technology, School of Computer Science and Engineering, Southeast University, Nanjing, People's Republic of China.

Physics in Medicine and Biology
|August 15, 2023
PubMed
Summary

This article presents a new computational method to improve image quality in Digital Breast Tomosynthesis. By identifying and correcting artifacts caused by dense calcifications, the technique helps radiologists see breast tissue more clearly, potentially increasing the accuracy of cancer screenings.

Keywords:
calcification artifact reductiondigital breast tomosynthesisimage fusionimage segmentationtomography reconstructionimage fusionhardening artifactsdiagnostic accuracy

Frequently Asked Questions

More Related Videos

Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
08:02

Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals

Published on: November 15, 2024

643
Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
04:40

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans

Published on: August 28, 2018

15.3K

Related Experiment Videos

Last Updated: Jul 19, 2025

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
13:44

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns

Published on: August 30, 2013

42.9K
Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
08:02

Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals

Published on: November 15, 2024

643
Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
04:40

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans

Published on: August 28, 2018

15.3K

Area of Science:

  • Medical imaging physics within diagnostic radiology
  • Digital Breast Tomosynthesis image processing techniques

Background:

No prior work has fully resolved the degradation of image quality caused by dense calcifications in breast screening. Traditional tomographic methods often struggle when high-attenuation features create significant visual noise. This noise obscures surrounding tissue and complicates clinical interpretation. That uncertainty drove researchers to seek better reconstruction strategies. Previous approaches often failed to balance artifact removal with the preservation of critical diagnostic details. High-density objects frequently trigger severe hardening effects during the scanning process. These distortions limit the overall diagnostic utility of current imaging systems. This gap motivated the development of specialized correction algorithms to address these specific technical challenges.

Purpose Of The Study:

The study aims to propose an efficient and accurate method for removing calcification artifacts in tomographic imaging. Researchers specifically address the hardening effects caused by high-attenuation features during the scanning process. These artifacts often reduce the quality of reconstructed images and hinder diagnostic accuracy. The team seeks to develop a solution that simultaneously eliminates noise and preserves critical calcification information. This objective stems from the need to improve the reliability of breast cancer screening procedures. By focusing on the projection phase, the authors intend to mitigate distortions before they propagate into the final volume. The motivation is to provide radiologists with clearer images for better clinical decision-making. This research explores how advanced image processing can overcome inherent limitations in current tomographic reconstruction techniques.

Main Methods:

The review approach centers on a multi-stage computational pipeline designed for tomographic data enhancement. First, the team implements a novel segmentation algorithm to isolate dense features within the projection space. Next, they apply an interpolation technique to mask out both the calcified regions and the associated hardening distortions. These modified projections undergo a standard reconstruction process to generate an artifact-free volume. Subsequently, the researchers perform a fusion operation between the interpolated reconstruction and the original unprocessed data. They utilize a custom voting strategy to determine the final pixel values. This design ensures that the structural integrity of the breast tissue remains intact. The investigators validated this pipeline using a diverse set of both synthetic and clinical datasets.

Main Results:

The researchers report that their algorithm effectively minimizes hardening artifacts across all tested datasets. They utilized 18 groups of simulated projection data to establish the baseline performance of the model. Additionally, the team processed 10 groups of real projection data to confirm clinical applicability. The findings demonstrate that the fusion strategy successfully removes visual noise while retaining necessary diagnostic information. This dual-objective achievement distinguishes their work from previous reconstruction methods. The results indicate a significant improvement in the clarity of high-attenuation features within the tomographic volumes. The authors observe that the voting mechanism provides a robust framework for image correction. These outcomes suggest that the proposed pipeline is highly capable of handling complex clinical imaging scenarios.

Conclusions:

The authors propose that their novel fusion strategy effectively mitigates hardening artifacts in tomographic images. This approach demonstrates superior performance compared to existing state-of-the-art techniques. By integrating interpolated data with original scans, the method maintains essential diagnostic information. The researchers suggest that this technique improves the clarity of reconstructed breast images. Their findings indicate a potential for more precise cancer screening protocols. The study highlights the utility of projection-based corrections in clinical imaging workflows. This work provides a foundation for future improvements in tomographic reconstruction accuracy. The team concludes that their algorithm successfully balances artifact reduction with the retention of vital anatomical features.

The researchers employ a projection correction based voting strategy. This mechanism identifies high-attenuation regions, interpolates the affected projection data, and fuses the resulting image with the original scan to eliminate artifacts while preserving the underlying calcification details.

The team utilizes a specialized segmentation method to isolate dense calcifications. This tool allows for the accurate identification of regions requiring interpolation, which is necessary to prevent the spread of hardening effects during the reconstruction process.

Interpolation is necessary because high-attenuation features create severe hardening artifacts that degrade the entire reconstructed volume. By removing these specific areas from the projection data, the algorithm prevents the propagation of visual noise into the final image.

The researchers use both simulated and real projection data. Specifically, they evaluated their algorithm using 18 groups of simulated data and 10 groups of real projection data to validate the robustness of the fusion strategy.

The authors measure the effectiveness of their approach by comparing the reduction of hardening artifacts against the retention of diagnostic information. They report that their algorithm successfully preserves effective image details while minimizing visual distortions.

The authors propose that this method paves the way for more efficient and precise breast cancer screening. They claim their approach is more advanced than current state-of-the-art techniques for handling high-attenuation features in tomographic imaging.