Artificial intelligence-enabled detection of vascular perfusion defects on ventilation/perfusion (V/Q) scintigraphy for pulmonary embolism
Related Experiment Video
Updated: Nov 1, 2026

Phase-Resolved Functional Lung MRI for Pulmonary Ventilation and Perfusion (V/Q) Assessment
Published on: August 9, 2024
Amir Jabbarpour1, Eric Moulton2, Sanaz Kaviani3
1Medical Physics, Carleton University, 1125 Colonel By Drive Ottawa, Ontario, K1S 5B6, CANADA, Ottawa, Ontario, K1S 5B6, Canada.
Objective:
Accurate interpretation of planar ventilation-perfusion (V/Q) scintigraphy, used for diagnosing pulmonary embolism (PE) based on PIOPED/EANM guidelines, requires objective assessment of mismatched V/Q defects. Manual delineation of V/Q defects is time-consuming, subject to interobserver variability, and rarely performed in practice, limiting standardized reporting and quantification of disease burden. To address these challenges, we evaluated four modern AI models for automated segmentation of vascular perfusion defects in planar V/Q scans and compared their performance to human annotators.
Approach:
We retrospectively identified 2,118 patients who underwent planar V/Q scans at The Ottawa Hospital (June 2019-February 2023). Six standard projections (ANT, POST, LAO, RAO, LPO, RPO) were included. Four 2D neural networks (U-Net, nnU-Net, Swin UNETR, and a Bottleneck Transformer U-Net [BTU-Net]) were trained on 1,313 patients (7,878 projections) and validated on 329 (1,974 projections) using physician-annotated defects. A hold-out test set of 46 high probability patients was used to evaluate segmentation quality, and defect detection accuracy using free-response receiver operating characteristic (FROC) analysis.
Main Results:
BTU-Net was the only model performing on par with human readers, showing robust sensitivity across the entire range of segmentation probabilities. At 1.5 false positives per projection rate (FPPR), BTU-Net outperformed other models with sensitivity of 0.529 ± 0.026, On a separate hold-out set of low likelihood of disease patients (n=430), the lowest FPPR was 0.08 ± 0.01 for BTU-Net (P<0.0001).
Significance:
BTU-Net enables rapid, consistent, and accurate interpretation of planar V/Q scans. Such tools may enhance diagnostic efficiency, standardize reporting, and support non-expert readers in evaluating PE.
More Related Videos
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...