Related Experiment Video
Updated: Jul 19, 2025

The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
Factors Influencing Noise Following Primary Ceramic-on-Ceramic Total Hip Arthroplasty
Yibin Zhang1, Yuhang Gao1, Yi Leng1
1Department of Bone and Joint Surgery, Orthopedic Center, The First Hospital of Jilin University, Changchun, Jilin, China.
Background:
The noise associated with ceramic-on-ceramic (CoC) total hip arthroplasty (THA) has been a concerning issue, while its underlying causes remain unclear.
Methods:
We conducted a retrospective analysis of 119 patients (174 primary CoC THAs) who had a mean follow-up of 28 months (range, 12 to 106). A questionnaire was designed to collect information on nature, frequency, onset, duration, and impact of the noise. Postoperative x-rays were evaluated. Clinical evaluations, including Harris and Oxford hip scores, were documented at follow-up time points (6 weeks, 3 months, 6 months, and 1 year).
Results:
Of the 174 hips, 31.6% reported noise, including 26 popping (14.9%), 24 clicking (12.1%), and 5 grinding (2.9%). No patients reported squeaking. Noisy hips had lower age (P = .009) and body mass index (P = .019). Among patients with developmental dysplasia of the hip, 17 of 55 hips reported noise associated with smaller cup anteversion angle (P = .004), greater body height (P = .022), and larger acetabular cup size (P = .049). Noise typically began at a mean of 193 days (range, 1 to 2,598) after surgery and disappeared spontaneously in 50.9% of hips before final follow-up, with an average disappearance time of 211 days (range, 60 to 730). Noise did not affect daily life in 74.5% of patients, while 26.9% of patients who had popping reported painful sensations. One patient experienced joint dislocation, and another experienced a ceramic liner fracture during follow-up. No statistical difference was observed in outcome scores between noise and silent groups at 4 follow-up time points.
Conclusions:
Incidence of noise after primary CoC THA is relatively high. Smaller cup anteversion and larger acetabular cup size were associated with noise production in patients who had developmental dysplasia of the hip.