Related Experiment Video
Updated: Jul 18, 2025

Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
Published on: March 11, 2017
Measurement of Hounsfield units on proximal femur computed tomography for predicting regional osteoporosis
Junlu Zhao1, Zhai Liu1, Qingyun Ren2
1Department of Radiology, The First Hospital of Hebei Medical University, 050031, Shijiazhuang, Hebei Province, China.
Objective:
This study was designed to investigate the use of proximal femoral Hounsfield units (HU) in conventional abdominal and pelvic computed tomography (CT) to predict hip osteoporosis by coupling with data from quantitative CT (QCT).
Methods:
In this study, 315 patients who underwent routine abdominal and pelvic CT with the proximal femur included in the scanning range were also subjected to QCT of the proximal femur. Pearson correlation test was performed to analyze the correlations of the femoral head, femoral neck, proximal femur, and femoral trochanter CT HU with the femoral neck, femoral trochanter, and intertrochanteric femur bone mineral density (BMD) values from QCT. The diagnostic performance of CT HU measurement of the proximal femur for osteoporosis was analyzed using receiver operating characteristic (ROC) curves.
Results:
The CT HU of the proximal femur showed the highest correlation with the BMD value of the hip (r = 0.826; p < 0.01). The mean CT HU of the proximal femur differed significantly (all p < 0.01) for the three QCT-defined BMD categories of osteoporosis (192.23 HU vs. 188.71), of osteopenia (247.86 HU vs. 248.36 HU), and of normal individuals (308.13 HU vs. 310.41 HU) in left and right sides, respectively. In the ROC curve analysis, the area under the ROC curve values to predict osteoporosis in the left and right proximal femurs were 0.942 and 0.941, respectively.
Conclusion:
The CT HU of the proximal femur was significantly associated with the BMD value of the hip measured by QCT. The CT HU of the proximal femur is highly effective in diagnosing osteoporosis and could be used for hip osteoporosis screening.
More Related Videos
09:02Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
06:59Author Spotlight: An Economic and Efficient Method for Quantitative Evaluation of Bone Microarchitecture in a Murine Osteoporosis Model
Published on: September 8, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT