Related Experiment Video
Updated: Jul 18, 2025

Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
Evaluation of the efficacy of transient overvoltages suppression measures in different wind farm topologies using SF6
Tamer Eliyan1,2, Fady Wadie3
1Faculty of Engineering at Shoubra, Benha University, Cairo, 11629, Egypt. tamer.alyan@feng.bu.edu.eg.
Abstract:
Various overvoltage mitigation schemes were used in literature in suppression of switching overvoltages in wind farms. However, the evaluation of how the effectiveness of these mitigation techniques would vary with the change of the wind farm topology is still un-explored territory. The main aim of this paper is to study the effectiveness of four mitigation schemes while using SF6 circuit breaker namely; R-L smart choke, R-C snubber circuit, surge capacitor and pre-insertion resistor (PIR) were studied in four different wind farm topologies; radial, single-sided ring, double-sided ring and star topologies. The topologies were based on a real wind farm located in Zaafrana, Egypt. The results showed that R-L choke to be the most effective scheme for all topologies followed by PIR, R-C snubber and surge capacitor schemes respectively. Their percentage of reduction of overvoltage ranged from 62 to 84% for R-L choke, 33-67% for PIR, 8-25% for R-C snubber circuits and 4-15% for surge capacitors. Also, it was shown that the change of the wind farm topology didn't affect the order of effectiveness of the mitigation schemes such that R-L remained the most effective and surge capacitor the least effective for all topologies.
More Related Videos
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
Related Concept Videos
Circuit Breaker and Fuse Selection
In high-voltage systems,...
Power System Three-Phase Short Circuits
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Generator Voltage Control
Series R—L Circuit Transients
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...