Related Experiment Video
Updated: Jul 18, 2025

In Vivo Assessment of Alveolar Macrophage Efferocytosis Following Ozone Exposure
Published on: October 22, 2019
A modal definition of ideal alveolar oxygen
Philip J Peyton1,2,3
1Department of Critical Care, Anaesthesia, Perioperative and Pain Medicine Program, Melbourne Medical School, University of Melbourne, Melbourne, Victoria, Australia.
Abstract:
In the three-compartment model of lung ventilation-perfusion heterogeneity (VA/Q scatter), both Bohr dead space and shunt equations require values for central "ideal" compartment O2 and CO2 partial pressures. However, the ideal alveolar gas equation most accurately calculates mixed (ideal and alveolar dead space) PAO2 . A novel "modal" definition has been validated for ideal alveolar CO2 partial pressure, at the VA/Q ratio in a lung distribution where CO2 elimination is maximal. A multicompartment computer model of physiological, lognormal distributions of VA and Q was used to identify modal "ideal" PAO2 , and find a modification of the alveolar gas equation to estimate it across a wide range of severity of VA/Q heterogeneity and FIO2 . This was then validated in vivo using data from a study of 36 anesthetized, ventilated patients with FIO2 0.35-80. Substitution in the alveolar gas equation of respiratory exchange ratio R with achieved excellent agreement (r2 = 0.999) between the calculated ideal PAO2 and the alveolar-capillary Pc'O2 at the modal VO2 point ("modal" Pc'O2 ), across a range of log standard deviation of VA 0.25-1.75, true shunt 0%-20%, overall VA/Q 0.4-1.6, and FIO2 0.18-1.0, where the modeled PaO2 was over 50 mm Hg. Modal ideal PAO2 can be reliably estimated using routine blood gas measurements.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
04:10Author Spotlight: Exploring Venous Waveforms for Non-Invasive Respiratory Monitoring in Pigs
Published on: March 8, 2024
Related Concept Videos
Respiratory Volumes and Capacities
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Alveoli and Alveolar Ducts
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...