Mitigating AC and DC Interference in Multi-ToF-Camera Environments
Abstract:
Multi-camera interference (MCI) is an important challenge faced by continuous-wave time-of-flight (C-ToF) cameras. In the presence of other cameras, a C-ToF camera may receive light from other cameras' sources, resulting in potentially large depth errors. We propose stochastic exposure coding (SEC), a novel approach to mitigate MCI. In SEC, the camera integration time is divided into multiple time slots. Each camera is turned on during a slot with an optimal probability to avoid interference while maintaining high signal-to-noise ratio (SNR). The proposed approach has the following benefits. First, SEC can filter out both the AC and DC components of interfering signals effectively, which simultaneously achieves high SNR and mitigates depth errors. Second, time-slotting in SEC enables 3D imaging without saturation in the high photon flux regime. Third, the energy savings due to camera turning on during only a fraction of integration time can be utilized to amplify the source peak power, which increases the robustness of SEC to ambient light. Lastly, SEC can be implemented without modifying the C-ToF camera's coding functions, and thus, can be used with a wide range of cameras with minimal changes. We demonstrate the performance benefits of SEC with thorough theoretical analysis, simulations and real experiments, across a wide range of imaging scenarios.
More Related Videos
09:55Bridging the Technology Divide in the COVID-19 Era: Using Virtual Outreach to Expose Middle and High School Students to Imaging Technology
Published on: September 28, 2022
16:10A TIRF Microscopy Technique for Real-time, Simultaneous Imaging of the TCR and its Associated Signaling Proteins
Published on: March 22, 2012
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Interference and Diffraction
Taping Over Different Ground Profiles
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
Light Acquisition
