Related Experiment Video
Updated: Jul 18, 2025

A Standardized Obstacle Course for Assessment of Visual Function in Ultra Low Vision and Artificial Vision
Published on: February 11, 2014
Development and Validation of the Low Vision Severely Constricted Peripheral Eyesight (LV-SCOPE) Questionnaire
Joshua R Ehrlich1, Chris Andrews2, Abigail Kumagai3
1From the Department of Ophthalmology and Visual Sciences (J.R.E., C.A., K.T.J., P.P.L.), University of Michigan, Ann Arbor, Michigan, USA; Institute for Social Research (J.R.E.), University of Michigan, Ann Arbor, Michigan, USA.
Purpose:
To develop and validate a novel patient-reported outcome (PRO) measure to assess vision-related functioning in individuals with severe peripheral field loss (PFL).
Design:
Prospective outcome measure development/validation study.
Methods:
A 127-item questionnaire was developed based on a prior qualitative interview study. A total of 116 participants with severe PFL due to retinitis pigmentosa (RP) or glaucoma were recruited at the Kellogg Eye Center and completed the Likert-scaled telephone-administered questionnaire. Included participants had a horizontal extent of their visual field <20 degrees (RP) or a mixed or generalized stage 4 to 5 defect using the Enhanced Glaucoma Staging System (glaucoma) in the better seeing eye (or in 1 eye if the fellow eye visual acuity was <20/200). Response data were analyzed using exploratory factor analysis and Rasch modeling. Poorly functioning items were eliminated, confirmatory factor analysis was used to ensure scale unidimensionality, and the model was refit to produce the final instrument.
Results:
The final Low Vision Severely Constricted Peripheral Eyesight (LV-SCOPE) Questionnaire contains 53 items across 6 domains: mobility, object localization, object recognition, reading, social functioning, and technology. There were 74 items removed because of high missingness, poor factor loadings, low internal consistency, high local dependency, low item information, item redundancy, or differential item functioning. Using Rasch item calibrations, person ability scores could be calculated for each of the 6 unidimensional LV-SCOPE domains with good test-retest stability.
Conclusions:
The LV-SCOPE Questionnaire provides a valid and reliable measure of vision-related functioning across 6 key domains relevant to individuals with severe PFL. Findings support the clinical utility of this psychometrically valid instrument.
More Related Videos
Related Concept Videos
Reliability and Validity
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Formulating and Validating Nursing Diagnosis II
Risk nursing diagnoses represent clinical judgments of an individual, family, or community more vulnerable to developing the health problem than others...
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...
Assessment of the Gastrointestinal System II: Health Perception Pattern
Health Perception Patterns
Health perception patterns offer valuable insights into a patient's lifestyle habits and how they may impact their GI health. These patterns include: