Related Experiment Video
Updated: Jul 18, 2025

Assessment of Boron Doped Diamond Electrode Quality and Application to In Situ Modification of Local pH by Water Electrolysis
Published on: January 6, 2016
An Interference-Free Voltammetric Method for the Detection of Sulfur Dioxide in Wine Based on a Boron-Doped Diamond
Eva Culková1, Zuzana Lukáčová-Chomisteková1, Renata Bellová1
1Electroanalytical Chemistry Laboratory, Department of Chemistry and Physics, Faculty of Education, Catholic University in Ružomberok, Hrabovská Cesta 1, SK-034 01 Ružomberok, Slovakia.
Abstract:
This paper describes a new, simple, and highly selective analytical technique for the detection of sulfur dioxide in wine, as a real sample with a relatively complicated matrix. The detection of the above analyte was based on the electrogeneration of iodine from iodide on a boron-doped diamond electrode, without modifications, in the presence of 0.1 mol dm-3 HClO4 as a supporting electrolyte. The electrogenerated iodine reacted with sulfur dioxide, forming iodide ions and sulfuric acid (i.e., a Bunsen reaction). The product of this reaction, the iodide ion, diffused back to the surface of the boron-doped diamond electrode and oxidized itself again. This chemical redox cycling enhanced the voltammetric response of the boron-doped diamond electrode. The selectivity of the determination was assured using NaOH and formaldehyde during sample preparation, and a blank was also measured and taken into account. The detection limit was estimated to be 10-6-10-7 mol dm-3. However, the content of sulfur dioxide in wine is significantly higher, which can lead to more accurate and reliable results.
More Related Videos
08:31Anaerobic Protein Purification and Kinetic Analysis via Oxygen Electrode for Studying DesB Dioxygenase Activity and Inhibition
Published on: October 3, 2018
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
Related Concept Videos
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Pulse Voltammetry
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetry: Factors Affecting Measurements
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetric Techniques: Cyclic Voltammetry