Piezoelectric Wafer Active Sensor Transducers for Acoustic Emission Applications
Connor Griffin1, Victor Giurgiutiu1
1Department of Mechanical Engineering, University of South Carolina, Columbia, SC 29208, USA.
Abstract:
Piezoelectric materials are defined by their ability to display a charge across their surface in response to mechanical strain, making them great for use in sensing applications. Such applications include pressure sensors, medical devices, energy harvesting and structural health monitoring (SHM). SHM describes the process of using a systematic approach to identify damage in engineering infrastructure. A method of SHM that uses piezoelectric wafers connected directly to the structure has become increasingly popular. An investigation of a novel pitch-catch method of determining instrumentation quality of piezoelectric wafer active sensors (PWASs) used in SHM was conducted as well as an investigation into the effects of defects in piezoelectric sensors and sensor bonding on the sensor response. This pitch-catch method was able to verify defect-less instrumentation quality of pristinely bonded PWASs. Additionally, the pitch-catch method was compared with the electromechanical impedance method in determining defects in piezoelectric sensor instrumentation. Using the pitch-catch method, it was found that defective instrumentation resulted in decreasing amplitude of received and transmitted signals as well as changes in the frequency spectrums of the signals, such as the elimination of high frequency peaks in those with defects in the bonding layer and an increased amplitude of around 600 kHz for a broken PWAS. The electromechanical impedance method concluded that bonding layer defects increase the primary frequency peak's amplitude and cause a downward frequency shift in both the primary and secondary frequency peaks in the impedance spectrum, while a broken sensor has the primary peak amplitude reduced while shifting upward and nearly eliminating the secondary peak.
More Related Videos
07:44Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Published on: April 27, 2016
10:39Fabrication and Characterization of Thickness Mode Piezoelectric Devices for Atomization and Acoustofluidics
Published on: August 5, 2020
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Clamper Circuit
Within this circuit, the diode's orientation prompts the capacitor to charge up to the level of the most negative peak of the input signal. Upon reaching this state, the diode ceases to conduct,...
Determination of Crystal Structures