Related Experiment Video
Updated: Jul 18, 2025

Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection
Published on: September 22, 2023
Calcium scoring on coronary computed angiography tomography with photon-counting detector technology: Predictors of
M Vecsey-Nagy1, A Varga-Szemes2, T Emrich3
1Heart and Vascular Center of Semmelweis University, Budapest, Hungary; Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA.
Introduction:
Obtaining accurate coronary artery calcium (CAC) score measurements from CCTA datasets with virtual non-iodine (VNI) algorithms would reduce acquisition time and radiation dose. We aimed to assess the agreement of VNI-derived and conventional true non-contrast (TNC)-based CAC scores and to identify the predictors of accuracy.
Methods:
CCTA datasets were acquired with either 120 or 140 kVp. CAC scores and volumes were calculated from TNC and VNI images in 197 consecutive patients undergoing CCTA. CAC density score, mean volume/lesion, aortic Hounsfield units and standard deviations were then measured. Finally, percentage deviation (VNI - TNC/TNC∗100) of CTA-derived CAC scores from non-enhanced scans was calculated for each patient. Predictors (including anthropometric and acquisition parameters, as well as CAC characteristics) of the degree of discrepancy were evaluated using linear regression analysis.
Results:
While the agreement between TNC and VNI was substantial (mean bias, 6.6; limits of agreement, 178.5/145.3), a non-negligible proportion of patients (36/197, 18.3%) were falsely reclassified as CAC score = 0 on VNI. The use of higher tube voltage significantly decreased the percentage deviation relative to TNC-based values (β = -0.21 [95%CI: 0.38 to -0.03], p = 0.020) and a higher CAC density score also proved to be an independent predictor of a smaller difference (β = -0.22 [95%CI: 0.37 to -0.07], p = 0.006).
Conclusion:
The performance of VNI-based calcium scoring may be improved by increased tube voltage protocols, while the accuracy may be compromised for calcified lesions of lower density. The implementation of VNI in clinical routine, however, needs to be preceded by a solution for detecting smaller lesions as well.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Acute Coronary Syndrome III: Diagnostic Studies
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography