Related Experiment Video
Updated: Jul 17, 2025

Energy Dispersive X-ray Tomography for 3D Elemental Mapping of Individual Nanoparticles
Published on: July 5, 2016
Dual-energy micro-focus computed tomography based on the energy-angle correlation of inverse Compton scattering
Yue Ma1,2, Dexiang Liu2, Jianfei Hua2
1Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China.
Background:
Inverse Compton scattering (ICS) source can produce quasi-monoenergetic micro-focus X-rays ranging from keV to MeV level, with potential applications in the field of high-resolution computed tomography (CT) imaging. ICS source has an energy-angle correlated feature that lower photon energy is obtained at larger emission angle, thus different photon energies are inherently contained in each ICS pulse, which is especially advantageous for dual- or multi-energy CT imaging.
Objective:
This study proposes a dual-energy micro-focus CT scheme based on the energy-angle correlation of ICS source and tests its function using numerical simulations.
Methods:
In this scheme, high- and low-energy regions are chosen over the angular direction of each ICS pulse, and dual-energy projections of the object are obtained by an angularly-splicing scanning method. The field-of-view (FOV) of ICS source is extended simultaneously through this scanning method, thus the scale of the imaging system can be efficiently reduced. A dedicated dual-energy CT algorithm is developed to reconstruct the monoenergetic attenuation coefficients, electron density, and effective atomic number distributions of the object.
Results:
A test object composed of different materials (carbon, aluminium, titanium, iron and copper) and line pairs with different widths (15/24/39/60 μm) is imaged by the proposed dual-energy CT scheme using numerical simulations, and high-fidelity monoenergetic attenuation coefficient, electron density, and effective atomic number distributions are obtained. All the line pairs are well identified, and the contrast ratio of the 15 μm lines is 22%, showing good accordance with the theoretical predictions.
Conclusions:
The proposed dual-energy CT scheme can reconstruct fine inner structures and material compositions of the object simultaneously, opening a new possibility for the application of ICS source in the field of non-destructive testing.
More Related Videos
10:18Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
Published on: February 21, 2017
12:24Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Imaging Studies III: Computed Tomography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...