Suppressed Concentration Quenching Brightens Short-Wave Infrared Emitters

Wenge Xiao1,2, Endale T Basore2, Guojun Zheng1

  • 1Institute of Light+X Science and Technology, College of Information Science and Engineering, Ningbo University, Ningbo, 315211, China.

Abstract

Related Concept Videos

Photoluminescence: Fluorescence and Phosphorescence01:23

Photoluminescence: Fluorescence and Phosphorescence

Photoluminescence is a process where a molecule absorbs light energy and re-emits it in the form of light. This phenomenon occurs when a substance absorbs photons, promoting its electrons to higher energy level excited states, followed by a relaxation process in which the electrons return to their original ground state energy levels and emit light. Photoluminescence is widely observed in various materials, including semiconductors, and organic and inorganic compounds.
A pair of electrons in a...
2.1K
Variables Affecting Phosphorescence and Fluorescence01:26

Variables Affecting Phosphorescence and Fluorescence

Fluorescence and phosphorescence are essential phenomena in fields like analytical chemistry, biological imaging, and materials science, where they detect molecular properties and visualize cellular structures. Understanding the variables that influence these luminescent behaviors is crucial for maximizing accuracy and efficiency in their applications. These variables can broadly be grouped into chemical structure, solvent properties, and external conditions, each playing a distinct role in...
527
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
429
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
225
IR Spectrum Peak Intensity: Amount of IR-Active Bonds00:55

IR Spectrum Peak Intensity: Amount of IR-Active Bonds

When infrared radiation is passed through a molecule, absorption occurs if the molecule's vibration leads to a substantial change in its bond dipole moment. Transitions between vibrational energy levels, typically corresponding to infrared frequencies (4000–400 cm−1), allow absorption if the vibration significantly alters the dipole moment, making the molecule infrared active. The molecular bonds have different stretching and bending vibrations, resulting in various peaks with...
659
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
641