Related Experiment Video
Updated: Jun 23, 2026

Gold Nanoparticle Modified Carbon Fiber Microelectrodes for Enhanced Neurochemical Detection
Published on: May 13, 2019
A highly efficient and portable laser-scribed graphene-based electrochemical system for forensic-oriented
Lucas F de Lima1, William R de Araujo1
1Portable Chemical Sensors Lab, Department of Analytical Chemistry, Institute of Chemistry, State University of Campinas - UNICAMP, P.O. Box 6154, 13083-970, Campinas, SP, Brazil. wra@unicamp.br.
Abstract:
Acepromazine (ACP) is a phenothiazine derivative drug commonly used as a tranquilizer veterinary medication due to its sedative properties. Benefiting from sedative properties, ACP has emerged as a drug of abuse and has been associated with drug-facilitated sexual assaults. Herein, we report, for the first time, the electrochemical behavior of ACP using a miniaturized and environmentally friendly laser-scribed graphene-based (LSG) sensor fabricated on a polyetherimide (PEI) substrate. The LSG device presented high porosity, as demonstrated by scanning electron microscopy (SEM). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements of the PEI-LSG electrode confirmed the enhanced electroactive area (3.1-fold increase) caused by the rough surface and revealed a low charge transfer resistance of the electrode material, with a heterogeneous electron transfer rate constant (k0) of 8.66 × 10-3 cm s-1 for potassium ferricyanide redox probe. A simple and accurate method was applied to quantify ACP by using square wave voltammetry (SWV) under optimized experimental conditions, which exhibited high sensitivity (0.686 ± 0.008 A L mol-1 cm-2) and a low limit of detection (LOD) of 7.43 × 10-8 mol L-1, with a linear concentration ranging from 0.5 to 100 μmol L-1 ACP. Aiming for on-site analysis, the PEI-LSG sensor was integrated with a miniaturized potentiostat controlled by using a smartphone and applied as proof of applicability to ACP detection in commercial beverage and synthetic urine samples. These studies demonstrated adequate recoveries, ranging from 95.1% to 115.8%. The analytical parameters highlight the robustness and reliability of the proposed method for analyses of ACP directly at a potential crime scene.
More Related Videos
07:51Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
09:39Exploring Biomolecular Interaction Between the Molecular Chaperone Hsp90 and Its Client Protein Kinase Cdc37 using Field-Effect Biosensing Technology
Published on: March 31, 2022