Hybrid Deep Morpho-Temporal Framework for Oscillometric Blood Pressure Measurement
Abstract:
Oscillometric blood pressure (BP) measurement devices are widely utilized as the primary automated BP measurement tools in non-specialist environments. However, their accuracy and reliability vary under different settings and for different age groups and health conditions. An essential constraint of current oscillometric BP measurement devices is their analysis algorithms' incapacity to capture the BP information encoded in the pattern of recorded oscillometric pulses to its fullest extent. In this article, we propose a new 2D oscillometric data representation that enables a full characterization of arterial system and empowers the application of deep learning to extract the most informative features correlated with BP. A hybrid convolutional-recurrent neural network was developed to capture the oscillometric pulses morphological information as well as their temporal evolution over the cuff deflation period from the 2D structure, and estimate BP. The performance of the proposed method was verified on three oscillometric databases collected from the wrist and upper arms of 245 individuals. It was found that it achieves a mean error and a standard deviation of error of as low as 0.08 mmHg and 2.4 mmHg in the estimation of systolic BP, and 0.04 mmHg and 2.2 mmHg in the estimation of diastolic BP, respectively. Our proposed method outperformed the state-of-the-art techniques and satisfied the current international standards for BP monitors by a wide margin. The proposed method shows promise toward robust and objective BP estimation in a variety of patients and monitoring situations.
Related Concept Videos
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: