Improved measurement of the glue layer in composite material by using sparse deconvolution.
Optics Letters
|September 1, 2023
Summary
Terahertz (THz) signal deconvolution algorithms accurately pinpoint echo arrival times in multilayered materials. These advanced methods enable faster, more reliable real-time inspection for industrial applications.
Area of Science:
- Physics
- Materials Science
- Signal Processing
Background:
- Terahertz (THz) technology offers superior penetration and resolution for inspecting thin layers in multilayered materials.
- Identifying echo arrival times in THz signals is difficult due to incident pulse shape and system noise.
Purpose of the Study:
- To develop and evaluate sparse deconvolution algorithms for precise THz echo time identification.
- To improve the accuracy and efficiency of THz-based material inspection.
Main Methods:
- Investigated two terahertz signal sparse deconvolution algorithms.
- Utilized the circulant structure of the convolution matrix to reduce computation time.
- Employed group velocity dispersion to mitigate time-varying pulse effects with low computational cost.
Main Results:
- Achieved accurate pinpointing of echo arrival times from experimental THz data.
- Reduced computation time to hundreds of milliseconds for the deconvolution methods.
- Demonstrated minimal computational expense for the group velocity dispersion method.
Conclusions:
- The developed algorithms enhance the accuracy of identifying thin glue layers using THz signals.
- Fast computation times and high confidence make these algorithms suitable for real-time industrial inspection.
- These advancements facilitate improved quality control in manufacturing processes.
Related Concept Videos
Deconvolution
186
Deconvolution, also known as inverse filtering, is the process of extracting the impulse response from known input and output signals. This technique is vital in scenarios where the system's characteristics are unknown, and they must be inferred from the observable signals.
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
186
Confocal Fluorescence Microscopy
13.4K
Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
13.4K
Measurement of Air Content in Concrete
180
Air content measurement in concrete is critical for ensuring structural integrity and durability of concrete structures, especially in environments prone to severe weather conditions. Accurate air content analysis optimizes concrete's resistance to freeze-thaw cycles and enhances its workability and strength. Several methods are standardized under ASTM guidelines to measure the air content in fresh concrete, each suitable for different concrete types and conditions.
The pressure method,...
The pressure method,...
180
Super-resolution Fluorescence Microscopy
7.0K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
7.0K