Related Experiment Video
Updated: Jul 17, 2025

Detection of Antibodies That Neutralize the Cellular Uptake of Enzyme Replacement Therapies with a Cell-based Assay
Published on: September 10, 2018
Anti-drug Antibody Magnitude and Clinical Relevance Using Signal to Noise (S/N): Bococizumab Case Study
Fred McCush1, Ellen Wang2, Carla Yunis3
1Clinical Pharmacology and Bioanalytics, Pfizer Research and Development, 445 Eastern Point Road, Groton, Connecticut, 06340, USA. Fred.Mccush@Pfizer.com.
Abstract:
Historically, the biopharmaceutical industry has used titer to characterize the magnitude of an anti-drug antibody (ADA) response. While reporting levels of antibodies in terms of titer is generally understood and accepted by regulatory and medical communities, titer values are inherently variable given the multiple serial dilutions and reporting a value either directly before or interpolated at the assay cut point on the lower plateau of the assay curve range. Using S/N is an appealing alternative approach to titer as it simplifies analysis with less dilutions, significantly reducing testing, time, and resources and provides a more precise value potentially differentiating low-level ADA responses. Current bridging electrochemiluminescence (ECL) ADA assays using Meso Scale Discovery (MSD) platform are also significantly more sensitive and drug tolerant with wider assay ranges compared to historic ELISA platforms; therefore, ADA response based on S/N may help differentiate and identify those ADA samples that are more likely to be clinically relevant. Bococizumab is a humanized monoclonal antibody targeting proprotein convertase subtilisin-kexin type 9 (PCSK9), which reduces plasma levels of low-density lipoprotein (LDL) cholesterol. Bococizumab was discontinued during Phase 3 clinical development based in part on the high rate of ADA and wide variation in LDL cholesterol responses among patients. The impact of anti-bococizumab antibodies on pharmacokinetic (PK) and pharmacodynamic (PD) endpoints was originally assessed using titer. Retrospective analysis of anti-bococizumab ADA responses using S/N ratios illustrates that S/N is an acceptable alternative to titer for characterizing the magnitude of ADA response and interpretation of clinically relevant ADA.
More Related Videos
10:19High-throughput Flow Cytometry Cell-based Assay to Detect Antibodies to N-Methyl-D-aspartate Receptor or Dopamine-2 Receptor in Human Serum
Published on: November 23, 2013
09:12A Protein Microarray Assay for Serological Determination of Antigen-specific Antibody Responses Following Clostridium difficile Infection
Published on: June 15, 2018