Related Experiment Video
Updated: Jul 17, 2025

Simulation of Human-induced Vibrations Based on the Characterized In-field Pedestrian Behavior
Published on: April 13, 2016
Lateral vibration data of an 18-story timber-concrete hybrid building obtained by on-site vibration tests
Yuji Miyazu1,2, Cristiano Loss2
1Department of Architecture, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510, Japan.
Abstract:
The dataset provided in this paper includes the lateral vibration data obtained by on-site vibration tests on an 18-story timber-concrete hybrid building, which was completed in 2017 and is located within the University of British Columbia campus in Vancouver, Canada. Aiming at evaluating vibration properties such as natural periods, damping ratios, and mode shapes, microtremor measurement (i.e., ambient vibration test) and human-powered excitation tests were conducted from March 27th to 29th, 2023. Lateral velocity data of the building were collected using eight servo velocity sensors, type VSE-15D, and a data acquisition system, type SPC-52, composed of an A/D converter and a DC amplifier. The voltage data picked up by the sensors was first converted to digital data and then transferred to the hard disk drive in a laptop through Ethernet. In the microtremor measurements, the lateral vibration in the longitudinal and the transverse directions of the test building were measured with three types of locations of the sensors in order to evaluate the vibration behavior along the height of the building and its torsional behavior. The human-powered excitation tests were carried out by pushing walls by eight persons in accordance with the fundamental frequency in the transverse direction, aiming at obtaining larger amplitude than with microtremor. The dataset is useful to deepen the understanding of the dynamic properties of tall timber-concrete hybrid buildings and encourage reasonable structural design and health monitoring of tall mass timber buildings.
Related Concept Videos
Vibrating Concrete
Prestressed Concrete
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Torsional Pendulum
As long as the rigid body's angular displacement is small, its oscillation can be modeled as a linear angular oscillation. The amplitude of the oscillation is an angle. The role of mass is played...
Non-destructive Tests for Concrete Strength

