Long-term Outcomes of Polytetrafluoroethylene Bicuspid Pulmonary Valve Replacement
Eung Re Kim1, Cheul Lee2, Chang-Ha Lee1
1Department of Thoracic and Cardiovascular Surgery, Sejong General Hospital, Bucheon-si, Gyeonggi-do, Republic of Korea.
Background:
In 2016 we reported promising midterm outcomes of bicuspid pulmonary valve replacement using 0.1-mm polytetrafluoroethylene (PTFE) membrane. This follow-up study analyzes long-term outcomes and risk factors for reintervention and structural valve deterioration (SVD).
Methods:
We performed a retrospective review of the original 119 patients who underwent PTFE bicuspid pulmonary valve replacement. Median patient age was 16.9 years (range, 0.4-57.1). Reintervention was defined as any surgical or percutaneous catheter procedure on the PTFE valve. SVD was defined as development of a peak pressure gradient ≥ 50 mm Hg or at least a moderate amount of pulmonary regurgitation on follow-up echocardiography.
Results:
The median follow-up duration was 9.5 years. The survival rate was 96.5% at 5 and 10 years, with 2 early and 2 late mortalities. Freedom from reintervention was 90.0% at 5 years and 63.3% at 10 years. Freedom from SVD was 92.8% at 5 years and 51.1% at 10 years, with regurgitation the predominant mode (64.6%). Freedom from both reintervention and SVD at 5 and 10 years were 89.1% and 49.5%, respectively. Multivariable analysis identified smaller valve diameter (hazard ratio, 0.82; P < .001) and more than trivial pulmonary regurgitation at discharge (hazard ratio, 5.81; P < .001) as risk factors for reintervention or SVD.
Conclusions:
Long-term results of the PTFE bicuspid pulmonary valve replacement were acceptable. However, improvements may be needed to reduce technical error and improve durability. Smaller valve diameter and more than trivial pulmonary regurgitation at discharge were risk factors for reintervention or SVD, warranting careful follow-up for timely reintervention.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
11:20A Rodent Model of The Ross Operation: Syngeneic Pulmonary Artery Graft Implantation in A Systemic Position
Published on: April 1, 2022
Related Concept Videos
Mitral Stenosis III: Medical Management
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Valve Prolapse II: Assessment and Management
Mitral Stenosis IV: Nursing Management
Mitral Stenosis I: Introduction
Endocarditis III: Medical Management