Related Experiment Video
Updated: Jul 17, 2025

Testing of Nanoparticle Release from a Composite Containing Nanomaterial Using a Chamber System
Published on: November 22, 2016
Nickel release from hairdressing tools in the United States
Cynthia X Chan1,2, Carsten R Hamann2,3
1Division of Dermatology, Montefiore Medical Center, Bronx, New York, USA.
Background:
Hairdressers have a high prevalence of contact dermatitis, especially to nickel. The presence of nickel in hairdressing tools has been evaluated in the European Union, where the government limits nickel release levels from objects.
Objectives:
The aim of this study is to qualitatively investigate nickel release in hairdresser tools in both rural and urban United States, a country without nickel release legislation.
Methods:
Hairdressers and individuals with hairdressing tools were invited to participate. Metallic parts of each tool were tested with dimethylglyoxime (DMG), which detects nickel release. Data on tool cost were recorded.
Results:
A total of 89 tools from 9 salons and 2 over-the-counter sets were tested. Twenty-four (27%) tested positive: trimmers (100%), curling irons (100%), clippers (50%), hair clips (36%), texturizing shears (26%), and trimming shears (4%). Nickel was detected in both salon and over-the-counter tools, and rural and urban salons. Nickel-releasing tools were cheaper than DMG-negative tools of the same type.
Conclusions:
Our findings help explain the high prevalence of contact dermatitis among hairdressers, alert clinicians to consider occult occupational nickel when assessing patients with allergic contact dermatitis, reinforces the importance of using barrier protection including gloves when handling hairdressing tools including at home, and augments impetus for more legislation regulating common allergens.
More Related Videos
03:07Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
06:53Author Spotlight: Rapid Prototyping and Testing of Self-Expanding Nitinol Frames for Transcatheter Implantable Devices
Published on: March 7, 2025
Related Concept Videos
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Handwashing II: Pre-procedure and Initial Procedure Steps
The hand washing procedure itself includes the following steps. First, cover cuts, if any, on hands with a waterproof dressing. Cuts and abrasions can become contaminated with bacteria hindering the ability to clean the area thoroughly. In addition, repeated hand washing can worsen an injury. The nails must be short and clean, without nail...
Electrodeposition
Electrodeposition can...