Accuracy of Root ZX Electronic Apex Locator in Relation to Two Different Employment Protocols: An In Vitro Study
Osama S Alothmani1, Amna Y Siddiqui1
1Department of Endodontics, King Abdulaziz University, Jeddah, SAU.
Abstract:
Objective The aim of this study is to determine the apical level of the root canal, whether it is the apical foramen or a level coronal to it, that Root ZX (J. Morita Co., Kyoto, Japan) targets and to identify its employment protocol that provides better accuracy. Methods Actual lengths (ALs) of 75 extracted single-rooted teeth were obtained by inserting a K-file size 8 until its tip was in level with the most coronal border of the apical foramen. Reference length (RL) was calculated by deducting 0.5 mm from AL. Roots were placed in porous sponge block soaked with Ringer's solution, and canals were irrigated with 2 mL of 5% sodium hypochlorite. The blinded operator used Root ZX to measure lengths with K-file size 8. In the first tested employment protocol, the file was advanced to the "APEX mark" of the digital display, and the length was obtained. The second employment protocol followed the manufacturer's recommendations by inserting the file until the "APEX mark" followed by its withdrawal to the "0.5 mark." Stability of the digital meter for 5 seconds was mandatory before recording the lengths. All measurements were repeated one week later and then both measurements were averaged to represent "APEX mark" and "0.5 mark," respectively. Data were analyzed using t-test, with significance set at 0.05. Results Regardless of the employment protocol, most registered lengths were longer than targeted. The mean "APEX mark" was significantly longer than the mean AL (P=0.000), and the mean "0.5 mark" was significantly longer than the mean RL (P=0.000). Although the mean "0.5 mark" was longer than the mean AL, the difference was not significant (P=0.07). Conclusion The apical level of the root canal targeted by the Root ZX was the apical foramen. The most accurate employment protocol to achieve that is to use the Root ZX according to the manufacturer's recommendations.
More Related Videos
09:02Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Related Concept Videos
Electronic Distance Measuring Instruments
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
Types of Global Positioning System Surveys
Field Application of Global Positioning System
Common Leveling Mistakes and Errors
Properties of the Root Locus
To determine if a point lies on the root locus, the criterion involves the sum of angles contributed by all poles and zeros to that point. Specifically, this sum must be an odd multiple of 180 degrees. The gain at any point on...