Related Experiment Video
Updated: Jul 17, 2025

A Rodent Model of The Ross Operation: Syngeneic Pulmonary Artery Graft Implantation in A Systemic Position
Published on: April 1, 2022
Unusual case of severe aortic regurgitation in a child with bicuspid aortic valve
Martina Avesani1, Jolanda Sabatino2, Domenico Sirico3
1Department of Women's and Children's Health, University of Padua; Pediatric Research Institute (IRP), Foundation Città Della Speranza, Padua. martiaavesani1@gmail.com.
Abstract:
Aortic regurgitation (AR) is common after aortic balloon valvuloplasty in children, and it has been associated with large balloon/annulus ratio, abnormal valve morphology, and aortic valve prolapse. We present a rare case of severe AR after aortic balloon valvuloplasty due to aortic strands rupture, causing prolapse of the co-joined cusp. These findings were identified by 3D echocardiography, highlighting the importance of this imaging technique even in pediatric patients.