Cardiac Amyloid Quantification Using 124I-Evuzamitide (124I-P5+14) Versus 18F-Florbetapir: A Pilot PET/CT Study
Olivier F Clerc1, Sarah A M Cuddy2, Matthew Robertson3
1Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA; Cardiac Amyloidosis Program, Cardiovascular Division, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
Background:
Cardiac amyloid quantification could advance early diagnosis of amyloid cardiomyopathy (CMP) and treatment monitoring. However, current imaging tools are based on indirect measurements. 124I-evuzamitide is a novel pan-amyloid radiotracer binding to amyloid deposits from multiple amyloidogenic proteins. Its ability to quantify cardiac amyloid has not yet been investigated.
Objectives:
The objectives of this pilot study were to quantify myocardial 124I-evuzamitide uptake and to compare its diagnostic value to 18F-florbetapir in participants with amyloid CMP and control subjects.
Methods:
This study included 46 participants: 12 with light-chain (AL) CMP, 12 with wild-type transthyretin (ATTRwt) CMP, 2 with hereditary amyloidosis, and 20 control subjects. All amyloidosis participants underwent positron emission tomography/computed tomography with 124I-evuzamitide and 18F-florbetapir. Control subjects underwent 124I-evuzamitide (n = 10) or 18F-florbetapir (n = 8) positron emission tomography/computed tomography. Left ventricular percent injected dose (LV% ID) was measured as mean activity concentration × myocardial volume/injected activity. High LV %ID was defined using Youden's index.
Results:
In CMP participants, median age was 74 years and 92% were men. 124I-evuzamitide LV %ID differed across groups: median AL-CMP 1.48 (IQR: 1.12-1.89), ATTRwt-CMP 2.12 (IQR: 1.66-2.47), and control subjects 0.00 (IQR: 0.00-0.01; overall P < 0.001). High LV %ID perfectly discriminated CMP from control subjects. Discrimination performance was similar for 18F-florbetapir LV %ID. Notably, for ATTRwt-CMP, LV %ID was higher with 124I-evuzamitide than 18F-florbetapir (P = 0.002). 124I-evuzamitide LV %ID was correlated with interventricular septum thickness (Spearman's ρ = 0.78) and LV global longitudinal strain (ρ = 0.54) from echocardiography, and with LV mass index (ρ = 0.82) and extracellular volume (ρ = 0.51) from cardiac magnetic resonance.
Conclusions:
124I-evuzamitide demonstrates uptake by cardiac amyloid and accurately discriminates amyloid CMP from control subjects. In AL-CMP, discrimination performance is similar to 18F-florbetapir. In ATTRwt-CMP, performance may be better with 124I-evuzamitide. Moderate-to-strong correlations of 124I-evuzamitide uptake with cardiac structural and functional metrics suggest valid amyloid quantification. Hence, 124I-evuzamitide is a promising novel radiotracer to detect and quantify cardiac amyloid.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET