Related Experiment Video
Updated: Jul 16, 2025

Collection and Extraction of Occupational Air Samples for Analysis of Fungal DNA
Published on: May 2, 2018
Co-Dependency of IAQ in Functionally Different Zones of Open-Kitchen Restaurants Based on Sensor Measurements
Monika Maciejewska1, Andi Azizah1, Andrzej Szczurek1
1Faculty of Environmental Engineering, Wroclaw University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wroclaw, Poland.
Abstract:
High-quality indoor air is essential in open-kitchen restaurants for ensuring a healthy workplace and comfortable conditions for visitors. In this study, indoor air quality interdependence between the kitchen and the dining zones in open-kitchen restaurants was analyzed. The method was based on measurements of selected air parameters using a sensor technique and mutual information (MI) analysis. A long-term approach (based on a several-hour time series) and a short-term approach (based on a several-minute time series) were applied. This study involved four open-kitchen restaurants. The indoor conditions were represented by the temperature, relative humidity, CO2 concentration, and content of the total volatile organic compounds (TVOC) in the air. The MI analyses showed that the long-term co-dependence of the indoor conditions between the kitchen and the dining zones was smaller during business hours (MI = 0.12 ÷ 0.40) compared to night hours (MI = 0.24 ÷ 0.58). The ranking of the long-term MI values for the individual air parameters was MICO2 (0.34) ≅ MIT (0.34) > MIRH (0.28) > MITVOC (0.23). The short-term interdependencies were smaller during night hours (median MI = 0.01 ÷ 0.56) compared to business hours (MI = 0.23 ÷ 0.61). Additionally, the short-term MI was subject to high temporal variability. The ranking of the short-term MI values for the individual air parameters was MICO2 (0.48) > MIT (0.46) > MIRH (0.37) > MITVOC (0.26). Due to the weak and highly variable co-dependence of the air parameters between the kitchen and dining areas, multi-zone monitoring of air parameters with an emphasis on TVOC measurements is recommended to ensure proper indoor conditions in open-kitchen restaurants. The presented approach may be applied to design indoor air quality monitoring and ventilation systems not only in open-kitchen restaurants but also in other interiors with functionally different zones.
More Related Videos
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
08:23Analyzing the Photo-oxidation of 2-propanol at Indoor Air Level Concentrations Using Field Asymmetric Ion Mobility Spectrometry
Published on: June 14, 2018
Related Concept Videos
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated....
Other Factors Affecting Respiration Centers
However, the ability to hold one's breath voluntarily is not limitless. When the CO2 concentration in the blood reaches a critical...
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This...
Factors Affecting Activity Coefficient
The activity coefficient value for an ion is close to one when the solution has almost zero ionic strength, i.e., when the solution shows close to ideal behavior. As the ionic strength of the solution increases from 0 to 0.1 mol/L, a...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...