Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Real-time Strain-encoding Cardiovascular MRI for Assessment of Regional Heart Function in Tetralogy of Fallot
El-Sayed H Ibrahim1, Prachi P Agarwal2, Maryam Ghadimi-Mahani2
1Department of Radiology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
Background:
Tetralogy of Fallot (ToF) is the most common form of cyanotic congenital heart disease, where right ventricular (RV) function is an important determinant of subsequent intervention.
Objective:
n this study, we evaluate the feasibility of fast strain-encoding (fastSENC; a one-heartbeat sequence) magnetic resonance imaging (MRI) for assessing regional cardiac function in ToF.
Method:
FastSENC was implemented to characterize regional circumferential (Ecc) and longitudinal (Ell) strains in the left ventricle (LV) and RV in postrepair ToF. Data analysis was conducted to compare strain measurements in the RV to those in the LV, as well as to those generated by the MRI Tissue-Tracking (MRI-TT) technique, and to assess the relationship between strain and ejection fraction (EF).
Results:
Despite normal LVEF (55±8.5%), RVEF was borderline (46±6.4%), but significantly lower than LVEF. RV strains (RV-Ell=-20.2±2.9%, RVEcc=- 15.7±6.4%) were less than LV strains (LV-Ell=-21.7±3.7%, LV-Ecc=-18.3±4.7%), and Ell was the dominant strain component. Strain differences between fastSENC and MRI-TT were less significant in RV than in LV. There existed moderate and weak correlations for RV-Ecc and RV-Ell, respectively, against RVEF. Compared to LV strain, RV strain showed regional heterogeneity with a trend for reduced strain from the inferior to anterior regions. Inter-ventricular strain delay was larger for Ell (64±47ms) compared to Ecc (36±40ms), reflecting a trend for contraction dyssynchrony.
Conclusion:
FastSENC allows for characterizing subclinical regional RV dysfunction in ToF. Due to its sensitivity for evaluating regional myocardial contractility patterns and real-time imaging capability without the need for breath-holding, fastSENC makes it more suitable for evaluating RV function in ToF.
More Related Videos
07:21Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking
Published on: February 12, 2011
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT