Related Experiment Video
Updated: Jul 16, 2025

Electrophysiological Measurements and Analysis of Nociception in Human Infants
Published on: December 20, 2011
The effect of oscillometric blood pressure measurement on pain response in preterm infants
Sumru Kavurt1, Zehra Arslan1, Sezin Unal1
1Department of Neonatology, Etlik Zubeyde Hanım Women's Health Training and Research Hospital, University of Health Sciences, Ankara, Turkey.
Aim:
Preterm neonates are exposed to many painful procedures in neonatal intensive care units. This study aims to evaluate the effect of oscillometric blood pressure (BP) measurement on pain response in preterm infants.
Methods:
This prospective study was performed over 4 months in a level III neonatal intensive care unit. Premature neonates whose gestational age was <34 weeks and postmenstrual age <36 weeks were included if they had no systemic diseases. BP measurement was performed on the right arm. The Premature Infant Pain Profile-Revised (PIPP-R) scores were evaluated three times before, during, and 10 min after BP measurement.
Results:
During the 5-month period, 100 preterm neonates (53 male infants) were included in the study. Median birth weight and gestational age of the infants were 1148 (IQR: 1015-1300) g and 28 (IQR: 27-30) weeks, respectively. PIPP-R scores were found to be ≥7 in 34% of neonates. PIPP-R scores increased during BP measurement and decreased after.
Conclusion:
Our results demonstrated that oscillometric BP measurement which is generally accepted as a non-invasive tool for monitoring can produce mild pain in premature neonates of postmenstrual age <36 weeks.
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure