Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
CARDIAC OUTPUT IN CRITICALLY ILL PATIENTS CAN BE ESTIMATED EASILY AND ACCURATELY USING THE MINUTE DISTANCE OBTAINED
Christian Villavicencio1, Xavier Daniel1, Marc Cartanyá1
1Critical Care Department, Joan XXIII-University Hospital, Tarragona, Spain.
Abstract:
Background: Cardiac output (CO) assessment is essential for management of patients with circulatory failure. Among the different techniques used for their assessment, pulsed-wave Doppler cardiac output (PWD-CO) has proven to be an accurate and useful tool. Despite this, assessment of PWD-CO could have some technical difficulties, especially in the measurement of left ventricular outflow tract diameter (LVOTd). The use of a parameter such as minute distance (MD) which avoids LVOTd in the PWD-CO formula could be a simple and useful way to assess the CO in critically ill patients. Therefore, the aim of this study was to evaluate the correlation and agreement between PWD-CO and MD. Methods: A prospective and observational study was conducted over 2 years in a 30-bed intensive care unit (ICU). Adult patients who required CO monitoring were included. Clinical echocardiographic data were collected within the first 24 h and at least once more during the first week of ICU stay. PWD-CO was calculated using the average value of three LVOTd and left ventricular outflow tract velocity-time integral (LVOT-VTI) measurements, and heart rate. Minute distance was obtained from the product of LVOT-VTI × heart rate. Pulsed-wave Doppler cardiac output was correlated with MD using linear regression. Cardiac output was quantified from the MD using the equation defined by linear regression. Bland-Altman analysis was also used to evaluate the level of agreement between CO calculated from MD (MD-CO) and PWD-CO. The percentage error was calculated. Results: A total of 98 patients and 167 CO measurements were analyzed. Sixty-seven (68%) were male, the median age was 66 years (interquartile range [IQR], 53-75 years), and the median Acute Physiology and Chronic Health Evaluation II score was 22 (IQR, 16-26). The most common cause of admission was shock in 81 patients (82.7%). Sixty-nine patients (70.4%) were mechanically ventilated, and 68 (70%) required vasoactive drugs. The median CO was 5.5 L/min (IQR, 4.8-6.6 L/min), and the median MD was 1,850 cm/min (IQR, 1,520-2,160 cm/min). There was a significant correlation between PWD-CO and MD-CO in the general population ( R2 = 0.7; P < 0.05). This correlation improved when left ventricular ejection fraction (LVEF) was less than 60% ( R2 = 0.85, P < 0.05). Bland-Altman analysis showed good agreement between PWD-CO and MD-CO in the general population, the median bias was 0.02 L/min, the limits of agreement were -1.92 to +1.92 L/min. The agreement was better in patients with LVEF less than 60% with a median bias of 0.005 L/min and limits of agreement of -1.56 to 1.55 L/min. The percentage error was 17% in both cases. Conclusion: Measurement of MD in critically ill patients provides a simple and accurate estimate of CO, especially in patients with reduced or preserved LVEF. This would allow earlier cardiovascular assessment in patients with circulatory failure, which is of particular interest in difficult clinical or technical conditions.
More Related Videos
06:10Author Spotlight: Assessment of Cardiac Output Calculation by Thermodilution in Pigs for Effective Perfusion Flow During EVLP
Published on: June 28, 2024
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...