Application of wireless energy transmission technology into central venous ports with light-emitting diodes
Mika Yasutomi1, Daisuke Yunaiyama2, Yuki Takara2
1Department of Radiology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan. mika911@tokyo-med.ac.jp.
Abstract:
Implantable central venous (CV) ports are widely used for chemotherapy and parenteral nutrition. Generally, CV ports are used safely; however, some patients suffer from drug leakage around the port septum due to mispuncture. Therefore, we developed a CV port that is visible under the skin. We created a prototype of a CV port using a 3D printer. Three red light-emitting diodes (LEDs) were attached around the septum that made the puncture site visible by applying wireless energy transmission technology using electromagnetic resonance. The CV port was implanted under the skin of pork rose meat. The thickness of the skin of pork loin was measured. Fifteen medical doctors participated in the study to visually confirm the lighted CV port. The visibility of the center of the septum with and without lights was scored 0 as non-diagnostic; 1, slightly visible; 2, well visible; and 3, obviously visible. The visibility with or without lights was assessed. The relationship between the years of experience and the visibility score was assessed. The Wilcoxon test was used for statistical analysis. LEDs were easily transmitted through the skin of pork rose meat. The median visibility scores with or without lights were 2 (range, 1-3) and 3 (range, 1-3), respectively (p = 0.005). No significant relationship was found between experience and visibility score (p = 0.289). CV ports with LEDs can be easily recognized compared with those without LEDs. This technique may contribute to medical safety by improving its visibility to avoid mispuncture.
More Related Videos
Related Concept Videos
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Peripheral Artery Disease IV: Nursing Management
Cardiac Catheterization IV: Nursing Management
Peripheral Artery Disease V: Postoperative Nursing Management
Light as Energy
Photons
A photon is a discrete electromagnetic particle or bundle of energy. Photons are characterized by their frequency, wavelength, and amplitude, similar to the properties of a wave. Waves with higher frequencies transmit more energy and have shorter wavelengths than longer wavelengths that transmit...