Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
Published on: June 9, 2016
Pico-tesla magnetic field detection with integrated flux concentrators using a multi-frequency modulation technique
Abstract:
In this paper, we implement integrated magnetic flux concentrators (MFCs) combined with a multi-frequency modulation method to achieve high-magnetic-detection sensitivity using a nuclear spin on the solid nuclear spin in diamonds. First, we excited the nuclear spin in diamonds using a continuous-wave technique, and a linewidth of 1.37 MHz and frequency resolution of 79 Hz were successfully obtained, which is reduced by one order of the linewidth, and increased by 56 times in frequency resolution compared to that excited by an electron spin. The integrated high-permeability MFC was designed to magnify the magnetic field near the diamond, with a magnification of 9.63 times. Then, the multi-frequency modulation technique was used to fully excite the hyperfine energy level of Nitrogen Vacancy (NV) centers along the four axes on the diamond with MFC, and magnetic detection sensitivity of 250p T/H z 1/2 was realized. These techniques should allow designing an integrated NV magnetometer with high sensitivity in a small volume.