Related Experiment Video
Updated: Jul 16, 2025

Extraction and Analysis of Cortisol from Human and Monkey Hair
Published on: January 24, 2014
Polished hollow core Bragg fiber sensor for simultaneous measurement of cortisol concentration and temperature
Abstract:
Disturbance of surrounding temperature inevitably affects the accuracy of fiber biosensors. To that end, we propose a compact label-free optofluidic sensor based on a polished hollow core Bragg fiber (HCBF) that can simultaneously measure the cortisol concentration and surrounding temperature in real-time. The sensor is comprised of fusion splicing single mode fiber (SMF), multimode fiber (MMF) and HCBF. HCBF is side polished to remove part of the cladding that the suspended inner surface of the fiber can contact the external environment. After the incident light passes through the MMF from the SMF, it enters the hollow area, high refractive index (RI) layers, respectively, where the anti-resonant reflecting optical waveguide (ARROW) guiding mechanism and Mach-Zehnder interferometer (MZI) are simultaneously excited. Taking advantage of the high RI layers of HCBF, compared to the fiber with uniform cladding, the light can be more confined in the cladding and more sensitive to inner surface medium. The inner surface of sensor is immobilized with cortisol aptamer for the sake of achieving high sensitivity and specific sensing of cortisol with the limit of detection (LOD) to be 4.303 pM. The proposed sensor has a compact structure, enables temperature compensation, and can be fabricated at low cost making it highly suitable for in-situ monitoring and high-precision sensing of cortisol and other biological analytes.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...