Related Experiment Video
Updated: Jul 16, 2025

Author Spotlight: Assessing the Reliability of Doppler Ultrasound in Measuring Leg Blood Flow
Published on: December 15, 2023
Health Belief Scale for Urinary Incontinence and Kegel Exercise: A Reliability and Validity Study
I Lknur Aydin Avci1,2, Özge Öz Yildirim1,2
1I˙lknur Aydin Avci, PhD, Health Science Faculty, Public Health Nursing Department, Ondokuz Mayıs University, Samsun, Turkey.
Purpose:
The aim of this study was to develop an instrument based on the Health Belief Model that measures urinary incontinence awareness and beliefs regarding pelvic floor muscle (Kegel) exercises.
Design:
Evaluation of validity and reliability of the novel instrument and analysis of sociodemographic variables based on responses to this 49-item scale.
Subjects And Setting:
The sample used to validate the instrument (n = 527) was drawn from patients cared for at the gynecology and obstetrics and urology polyclinic at Ondokuz Mayıs University Hospital. A majority of participants were female (n = 431, 81.8%) and their average age was 33.8 years (SD 12.3). The university is located in Samsun, a city located in northern Turkey. Data were collected between October 2019 and December 2020.
Methods:
The Health Belief Scale for Urinary Incontinence and Kegel Exercise's validity was analyzed using a content validity index approach with 8 experts. Psychometric measurements were obtained using exploratory factor analysis and Cronbach's α reliability analysis. Exploratory factor analysis incorporated principal component analysis and varimax rotation. t Tests and 1-way analysis of variance were used to compare subdimensions of the Health Belief Scale for Urinary Incontinence and Kegel Exercise with some variables (sex, education status, marital status, make Kegel exercises regularly, etc).
Results:
Results supported a scale having 49 items and 6 subscales per factor analysis explaining 59.8% of total variance. With exploratory factor analysis, the Kaiser-Meyer-Olkin coefficient was 0.899 and Barlett test result was χ² = 18389.424 (P = .001). Cronbach's α coefficients for the scale varied between 0.79 and 0.94. Factor loadings per underlying dimensions ranged from 0.42 to 0.84.
Conclusion:
The Health Belief Scale for Urinary Incontinence and Kegel Exercise is a valid and reliable instrument.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
07:27Exergaming in Older People Living with HIV Improves Balance, Mobility and Ameliorates Some Aspects of Frailty
Published on: October 6, 2016
Related Concept Videos
Reliability and Validity
Nursing Assessment of the Genitourinary System I: Health History
Urine Studies II: Urine Culture and Sensitivity Test
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Assessment of the Gastrointestinal System II: Health Perception Pattern
Health Perception Patterns
Health perception patterns offer valuable insights into a patient's lifestyle habits and how they may impact their GI health. These patterns include:
Nursing Assessment of the Genitourinary System III: Percussion and Auscultation