Related Experiment Video
Updated: Jul 16, 2025

Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Accuracy in Polyp Size Measurement Among Surgeons, Gastroenterologists, Trainees, and Experts: A Prospective
Roupen Djinbachian1,2, Ioana Popescu Crainic1,3, Mathieu Pioche4
1Montreal University Hospital Research Center, Montreal, Quebec, Canada.
Introduction:
Polyp size determination plays an important role in endoscopic decision making and follow-up determination. However, there is a lack of knowledge of endoscopist accuracy for polyp sizing and efficacy of available tools for size measurement. Our aim was to compare the accuracy of visual assessment, snare, forceps, and virtual scale endoscope (VSE) in estimating polyp size among a diverse group of endoscopists.
Methods:
We conducted a prospective video-based study. One hundred twenty polyps measured and recorded along with all available measurement tools were randomized to visual assessment, snare, forceps, or VSE group. Eleven endoscopists conducted video-based measurement using the randomized measurement tool. Primary outcome was relative accuracy in polyp size measurement compared with caliper measurement immediately postresection.
Results:
One thousand three hundred twenty measurements were performed. VSE had statistically significantly higher relative accuracy when compared to forceps (79.3 vs 71.3%; P < 0.0001). Forceps had statistically significantly higher relative accuracy when compared to visual assessment (71.3 vs 63.6%; P = 0.0036). There was no statistically significant difference when comparing visual assessment and snare-based measurements (63.6 vs 62.8%; P = 0.797). Overall, 21.5% of polyps >5 mm were misclassified as ≤5 mm and 17.3% of polyps ≥10 mm were misclassified as <10 mm. VSE had the lowest percentage of polyps >5 mm misclassified as ≤5 mm (2.6%), polyps ≤5 mm misclassified as >5 mm (5.1%), and polyps <10 mm misclassified as ≥10 mm (1.7%).
Discussion:
Visual size estimation of polyps is inaccurate independently of training level, sex, and specialty. Size measurement accuracy can be improved using forceps and yields the highest relative accuracy when an adaptive scale technology is used.
Related Concept Videos
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures III: Video Capsule Endoscopy